MétaCan
Menu
← Back to cohort
Record W4402069632 · doi:10.1111/cid.13366

Fibrin clot adherence on cleaned and decontaminated titanium abutment surfaces: An in vitro study

2024· article· en· W4402069632 on OpenAlexvenueno aff
Habibe Öztürk Ulusoy, Esra Ercan, Orhan Özatik, Mustafa Tunalı

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2024
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsFibrinTitaniumDentistryIn vitroAbutmentMedicineBiomedical engineeringMaterials scienceChemistryMetallurgyEngineeringImmunologyBiochemistry

Abstract

fetched live from OpenAlex

STATEMENT OF PROBLEM: Osseointegration is now primarily established, but soft tissue integration is still susceptible to failure and problematic on implant surfaces. So, implant dentistry is increasingly focusing on improving peri-implant soft tissue integration. PURPOSE: The present study aimed to evaluate the blood fibrin clot formation and adhesion on the abutment after cleaning and decontamination and determine the suitable abutment surface associated with fibrin clot attachment. MATERIALS AND METHODS: Forty-two abutments (14 per group) were used in the present study: a brand-new (BN), contaminated with biofilm (CO) and decontaminated with an enzymatic cleaner and autoclave sterilization (DEC). For a fibrin clot, 9 mL of whole human blood and abutments was centrifuged at 2700 rpm for 12 min. Clots were divided into two parts for histomorphometry and scanning electron microscopy (SEM) analysis. Twelve abutments disconnected from the clot and two not treated with blood were observed under SEM. RESULTS: Residual debris and biofilm were observed on the abutment surface in the CO group but not in other groups. Healthy and organized fibrin clots formed on all abutments. The fibrin extension areas are distributed uniformly in BN and DEC groups but irregularly in CO. The surface percentage of the fibrin clot extensions was 41.76% ± 6.73, 26.99% ± 6.40, and 37.83% ± 9.72 for the BN, CON, and DEC groups, respectively. The blood clot-attached areas in the CO group were statistically lower than the other groups. No difference was observed between the BN and DEC groups. CONCLUSIONS: This study confirmed that surface contamination could influence blood clot attachment on the abutment surfaces. Cleaning and sterilization can have a favorable effect on soft tissue healing on abutment surfaces.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.160
GPT teacher head0.497
Teacher spread0.337 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→