P078 Microsnare retrieval as a bail-out technique of Detached Woven EndoBridge device: Illustrative series
Bibliographic record
Abstract
<h3>Introduction</h3> The Woven EndoBridge (WEB) device (MicroVention, Tustin, CA, USA) has an excellent safety profile. While major complications such as device malposition and migration are rare, they can have serious consequences if not addressed promptly. <h3>Aim of Study</h3> Our case series describes the safety and efficacy of Amplatz goose neck microsnare device (Medtronic in Irvine, CA, USA) in endovascular retrieval of a detached WEB device. <h3>Methods</h3> We retrospectively reviewed six consecutive patients who underwent endovascular WEB retrieval using Amplatz microsnare device between March 2012 and December 2022. <h3>Results</h3> All six WEB devices were successfully retrieved either directly from the aneurysm sac due to device malpositioning or from a distal branch following device migration. None of the patients experienced intra-operative aneurysm perforation, arterial dissection, or vasospasm attributable to the process of WEB extraction. Five out of six patients (83.3%) had a good functional outcome (mRS 0-1) upon discharge from the hospital and at 24 months. <h3>Conclusion</h3> Our experience suggests that detached WEB devices can be safely retrieved using an Amplatz microsnare. Apart from addressing device migration, direct removal of an undersized or malpositioned WEB from the aneurysm sac appears to be a safe option that can be considered when all other rescue techniques have been exhausted. <h3>Disclosure of Interest</h3> no.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; both teacher heads agree on what is shown here.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".