MétaCan
Menu
Back to cohort
Record W4403071173 · doi:10.1093/clinchem/hvae106.607

B-250 Analytical and Diagnostic Performance Evaluation of Plasma pTau217 in a Clinical Diagnostic Laboratory

2024· article· en· W4403071173 on OpenAlexaff
H Frykman, Anna Mammel, D. R. Biehl, Mary Joy Encarnacion, K.G. Hallett, Ging‐Yuek Robin Hsiung, Alireza Mousavi

Bibliographic record

VenueClinical Chemistry · 2024
Typearticle
Languageen
FieldMedicine
TopicHemoglobinopathies and Related Disorders
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsDiagnostic testMedicineMedical physicsPediatrics

Abstract

fetched live from OpenAlex

Abstract Background Blood-based biomarkers are a readily accessible and cost-effective screening tool for Alzheimer’s disease (AD). Phosphorylated tau 217 (pTau217) is a specific biomarker for diagnosis and differentiating of AD. It is also a reliable biomarker for facilitating more timely access to disease-modifying therapies. Here, we report the analytical and clinical performance of plasma pTau 217 using high-sensitivity methodologies in a clinical diagnostic laboratory. Methods The analytical performance, including precision, specificity, detection limits, and linearity, as well as analyte stability, was assessed. Plasma pTau217 levels were measured using ALZpath pTau217 assay on the Quanterix HD-X Simoa® platform or LUMIPULSE plasma pTau217 on the Lumipulse G1200 platform. Clinical Validation conducted at Neurocode USA & BC Neuroimmunology involving 263 samples with amyloid PET data, 219 healthy aging samples and 150 Pathology confirmed samples. Results The mean plasma pTau 217 concentrations in healthy aging samples were 0.22 ± 0.08 ng/L. ALZpath pTau217 assay has an analytical measurement range of 0.06 - 10 pg/mL, with a limit of blank (LoB) of 0.0035 ng/L, a limit of detection (LoD) of 0.0074 ng/L, and a limit of quantification (LoQ) of 0.0600 ng/L. Its linearity extends from 0.19 to 2.8 ng/L, with repeatability demonstrating intra-laboratory precision above LoQ ≤ 20% CV. Stability is maintained at 4⁰C for ≤ 1 week, at room temperature for ≤ 24 hrs, at -20⁰C for ≤ 4 weeks, and at -80⁰C for ≤ 4 weeks, with freeze/thaw cycles tolerated up to 5 times. Furthermore, no interference was detected at the maximum concentrations tested for bilirubin, hemoglobin, biotin, and heterophilic antibodies. ROC analysis yielded an AUC of 0.92 to 0.93, identifying a suitable clinical cutoff of < 0.4 ng/L. Conclusions The outstanding clinical and analytical performance of pTau217 supports its adoption as a robust screening tool in clinical practice, facilitating accurate and reliable diagnosis of AD by clinicians.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.023
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.249
Threshold uncertainty score0.985

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.023
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.384
Teacher spread0.344 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueClinical ChemistrySame topicHemoglobinopathies and Related DisordersFrench-language works237,207