MétaCan
Menu
Back to cohort
Record W4403079640 · doi:10.1002/jor.25981

Evaluation of conventional and CT‐based radiostereometric analysis for inducible displacement measurements after total hip arthroplasty

2024· article· en· W4403079640 on OpenAlexafffund
J Polus, Bart L. Kaptein, Edward M. Vasarhelyi, Brent A. Lanting, Matthew G. Teeter

Bibliographic record

VenueJournal of Orthopaedic Research® · 2024
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsWestern University
FundersMicroPortUniversiteit LeidenStrykerLeids Universitair Medisch CentrumArthritis SocietyOrthopaedic Research Society
KeywordsSupine positionNuclear medicineMedicineTotal hip arthroplastyTranslation (biology)ImplantDisplacement (psychology)SurgeryPsychologyChemistry

Abstract

fetched live from OpenAlex

Though radiostereometric analysis (RSA) is the gold standard for migration tracking, computed tomography-based RSA (CT-RSA) does not require marker beads and is available for clinical adoption. This study investigated CT-RSA in comparison to RSA for assessing hip implant stability with inducible displacement (ID) examinations. Patients (n = 48) from a previous study returned to be re-examined for femoral stem stability with CT-RSA and RSA imaging. Implant migration since patients last follow-up was calculated as a measure of stability. ID was assessed between alternated leg rotation scans for CT-RSA and between supine and weight-bearing scans for RSA. Measurements from ID and double examinations were compared between CT-RSA and RSA. All stems were well-fixed with migration <0.2 mm/year. ID measurements were lower with CT-RSA than RSA for distal translation (mean difference = 0.122 mm, p < 0.0001), total translation (mean difference = 0.158 mm, p < 0.0001), and total rotation (mean difference = 0.449°, p < 0.0001). The ID and double exam were significantly different for total translation and total rotation for CT-RSA, and significantly different for medial, distal, and total translation, and total rotation for RSA. Precision ranged from 0.049 to 0.130 mm in translation and 0.061° to 0.220° in rotation for CT-RSA, and from 0.108 to 0.269 mm in translation and 0.151° to 0.670° in rotation for RSA. ID measurements from both CT-RSA and RSA were minimal, consistent for a cohort with well-fixed stems. CT-RSA demonstrated superior precision in all axes compared to RSA. Clinical Significance: Future work should explore the use of CT-RSA in patients with suspected loosening as a potential diagnostic tool.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.167
GPT teacher head0.412
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Orthopaedic Research®Same topicOrthopaedic implants and arthroplastyFrench-language works237,207