MétaCan
Menu
Back to cohort
Record W4403276884 · doi:10.1007/s00259-024-06938-w

Spiral volumetric optoacoustic tomography of reduced oxygen saturation in the spinal cord of M83 mouse model of Parkinson’s disease

2024· article· en· W4403276884 on OpenAlexaff
Benjamin F. Combes, Sandeep Kumar Kalva, Pierre‐Louis Benveniste, Agathe Tournant, Man Hoi Law, Joshua Newton, Maik Krüger, R. Weber, Inês Dias, Daniela Noaín, Xose Luis Dean-Ben, Uwe Konietzko, Christian R. Baumann, Per-Göran Gillberg, Christoph Höck, Roger M. Nitsch, Julien Cohen‐Adad, Daniel Razansky, Ruiqing Ni

Bibliographic record

VenueEuropean Journal of Nuclear Medicine and Molecular Imaging · 2024
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsPolytechnique MontréalMila - Quebec Artificial Intelligence Institute
FundersUniversität ZürichEidgenössische Technische Hochschule ZürichSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
KeywordsSpinal cordEx vivoMedicineMagnetic resonance imagingPathologyPreclinical imagingIn vivoAnatomyRadiologyBiology

Abstract

fetched live from OpenAlex

Abstract Purpose Metabolism and bioenergetics in the central nervous system play important roles in the pathophysiology of Parkinson’s disease (PD). Here, we employed a multimodal imaging approach to assess oxygenation changes in the spinal cord of the transgenic M83 murine model of PD overexpressing the mutated A53T alpha-synuclein form in comparison with non-transgenic littermates. Methods In vivo spiral volumetric optoacoustic tomography (SVOT) was performed to assess oxygen saturation (sO 2 ) in the spinal cords of M83 mice and non-transgenic littermates. Ex vivo high-field T1-weighted (T1w) magnetic resonance imaging (MRI) at 9.4T was used to assess volumetric alterations in the spinal cord. 3D SVOT analysis and deep learning-based automatic segmentation of T1w MRI data for the mouse spinal cord were developed for quantification. Immunostaining for phosphorylated alpha-synuclein (pS129 α-syn), as well as vascular organization (CD31 and GLUT1), was performed after MRI scan. Results In vivo SVOT imaging revealed a lower sO 2 SVOT in the spinal cord of M83 mice compared to non-transgenic littermates at sub-100 μm spatial resolution. Ex vivo MRI-assisted by in-house developed deep learning-based automatic segmentation (validated by manual analysis) revealed no volumetric atrophy in the spinal cord of M83 mice compared to non-transgenic littermates at 50 μm spatial resolution. The vascular network was not impaired in the spinal cord of M83 mice in the presence of pS129 α-syn accumulation. Conclusion We developed tools for deep-learning-based analysis for the segmentation of mouse spinal cord structural MRI data, and volumetric analysis of sO 2 SVOT data. We demonstrated non-invasive high-resolution imaging of reduced sO 2 SVOT in the absence of volumetric structural changes in the spinal cord of PD M83 mouse model.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.793
Threshold uncertainty score0.323

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.300
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Nuclear Medicine and Molecular ImagingSame topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207