MétaCan
Menu
Back to cohort
Record W4403353157 · doi:10.1021/acs.analchem.4c02479

Laminar Flow Infrared Spectroelectrochemistry

2024· article· en· W4403353157 on OpenAlexafffund
Linlin Liu, Nan Jia, Ian J. Burgess, Jesse Greener

Bibliographic record

VenueAnalytical Chemistry · 2024
Typearticle
Languageen
FieldChemistry
TopicElectrochemical Analysis and Applications
Canadian institutionsCentre hospitalier de l'Université LavalUniversity of SaskatchewanUniversité Laval
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryFourier transform infrared spectroscopyAscorbic acidAttenuated total reflectionFerrocyanideElectrodeAnalytical Chemistry (journal)Laminar flowInfraredInfrared spectroscopyChemical engineeringOrganic chemistryOptics

Abstract

fetched live from OpenAlex

In this work, we advance lab-on-chip electrochemistry and spectroscopy by combining these capabilities onto a single platform, thereby achieving mid-infrared spectroelectrochemistry (SEC) for the first time. The key feature of this technique is the use of deterministic laminar flow patterns to precisely transport a reacted solution from upstream electrodes to a downstream spectral detection region. Laminar flow spectroelectrochemistry (LF-SEC) is therefore a completely new approach, which derives its distinction and advantage over traditional SEC by physically separating electrode and attenuated total reflection (ATR) elements. As such, these functional elements retain optimal properties, such as inert, highly conductive electrodes and a bare ATR element for sensitive Fourier transform infrared (FTIR) spectroscopy. By combining ATR-FTIR with a scanning aperture system, LF-SEC provides the additional advantage of spectroscopically monitoring reactions at individual electrodes. The LF-SEC system design is first optimized through a series of targeted experiments using a ferricyanide/ferrocyanide redox pair to validate electrochemical functionality, undertake spectroscopic calibration, optimize experimental parameters, and finally validate the quantitative relationship between FTIR results and the reaction rate under galvanostatic control. After optimization, we demonstrate the technique by monitoring the oxidation of the therapeutic compound ascorbic acid (vitamin C) in the presence of biomolecular interference from a molecule with an overlapping oxidation potential. We find that molecular availability causes the reaction to switch between reaction pathways, which we could finely monitor using LF-SEC. This work opens the door to future developments that take advantage of the microfluidic reactor setup, with benefits ranging from portability to high-throughput studies under precise reaction conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.691
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0090.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.237
Teacher spread0.231 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicElectrochemical Analysis and ApplicationsFrench-language works237,207