MétaCan
Menu
Back to cohort
Record W4403606092 · doi:10.3390/info15100638

Voltage Deviation Improvement in Microgrid Operation through Demand Response Using Imperialist Competitive and Genetic Algorithms

2024· article· en· W4403606092 on OpenAlexafffund
Mahdi Ghaffari, Hamed H. Aly

Bibliographic record

VenueInformation · 2024
Typearticle
Languageen
FieldEngineering
TopicSmart Grid Energy Management
Canadian institutionsDalhousie University
FundersMitacs
KeywordsMicrogridVoltageDemand responseGenetic algorithmComputer scienceAlgorithmImperialist competitive algorithmMathematical optimizationControl theory (sociology)EngineeringMathematicsMachine learningArtificial intelligenceElectrical engineeringElectricityControl (management)Meta-optimization

Abstract

fetched live from OpenAlex

In recent decades, with the expansion of distributed energy generation technologies and the increasing need for more flexibility and efficiency in energy distribution systems, microgrids have been considered a promising innovative solution for local energy supply and enhancing resilience against network fluctuations. One of the basic challenges in the operation of microgrids is the optimal management of voltage and frequency in the network, which has been the subject of extensive research in the field of microgrid operational optimization. The energy demand is considered a crucial element for energy management due to its fluctuating nature over the day. The use of demand response strategies for energy management is one of the most important factors in dealing with renewables. These strategies enable better energy management in microgrids, thereby improving system efficiency and stability. Given the complexity of optimization problems related to microgrid management, evolutionary optimization algorithms such as the Imperialist Competitive Algorithm (ICA) and Genetic Algorithm (GA) have gained great attention. These algorithms enable solving high-complexity optimization problems by considering various constraints and multiple objectives. In this paper, both ICA and GA, as well as their hybrid application, are used to significantly enhance the voltage regulation in microgrids. The integration of optimization techniques with demand response strategies improves the overall system efficiency and stability. The results proved that the hybrid method provides valuable insights for optimizing energy management systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.223
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueInformationSame topicSmart Grid Energy ManagementFrench-language works237,207