MétaCan
Menu
Back to cohort
Record W4403714421 · doi:10.1016/j.phro.2024.100661

Proof-of-concept of real-time electromagnetic guidance for gynecologic interstitial catheters in high dose rate brachytherapy

2024· article· en· W4403714421 on OpenAlexaff
Audrey Cantin, Marie‐Claude Lavallée, Éric Poulin, Gilion Hautvast, William Foster, Luc Beaulieu

Bibliographic record

VenuePhysics and Imaging in Radiation Oncology · 2024
Typearticle
Languageen
FieldMedicine
TopicEndometrial and Cervical Cancer Treatments
Canadian institutionsUniversité LavalHôtel-Dieu de QuébecCentre hospitalier de l'Université Laval
Fundersnot available
KeywordsBrachytherapyDose rateMedicineProof of conceptMedical physicsComputer scienceRadiologyRadiation therapy

Abstract

fetched live from OpenAlex

Background and Purpose: The addition of interstitial needles to intracavitary gynecologic (GYN) high dose rate (HDR) brachytherapy has been shown to improve target coverage and organs-at-risk (OAR) sparing. However, no commercial solution allows real-time guidance of interstitial catheter placement. This phantom study aimed to evaluate the feasibility of an electromagnetic (EM) tracking system guidance workflow for GYN HDR brachytherapy treatment in a magnetic resonance imaging (MRI) and real-time transrectal ultrasound (TRUS) fusion scenario. Materials and Methods: A clinical investigational system combining a treatment planning system and the EM tracking technology was used. The 3D T2 weighted magnetic resonance (MR) image set of a patient treated with intracavitary and interstitial HDR brachytherapy was retrospectively chosen. The MR image set was used to delineate the target and the OARs. A preplan was generated to determine needles positions in advance. The implant was reproduced in a water phantom. A 3D TRUS scan was acquired, and a rigid registration between the MR and the TRUS images was performed. Results: The accuracy of the EM tracking system was < 1 mm for both the sagittal and the transverse modes of the TRUS probe. Contours that were delineated on the MRI were propagated on the TRUS images after the rigid registration. Needle insertion was successfully guided in real time with the EM tracking system on the TRUS live image using the MRI contours for guidance. Conclusion: Based on this proof-of-concept, real-time EM-guidance of interstitial needle for GYN HDR brachytherapy appears to be feasible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.927
Threshold uncertainty score0.287

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.319
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuePhysics and Imaging in Radiation OncologySame topicEndometrial and Cervical Cancer TreatmentsFrench-language works237,207