MétaCan
Menu
Back to cohort
Record W4403714421 · doi:10.1016/j.phro.2024.100661

Proof-of-concept of real-time electromagnetic guidance for gynecologic interstitial catheters in high dose rate brachytherapy

2024· article· en· W4403714421 on OpenAlexaff
Audrey Cantin, Marie‐Claude Lavallée, Éric Poulin, Gilion Hautvast, William Foster, Luc Beaulieu

Bibliographic record

VenuePhysics and Imaging in Radiation Oncology · 2024
Typearticle
Languageen
FieldMedicine
TopicEndometrial and Cervical Cancer Treatments
Canadian institutionsUniversité LavalHôtel-Dieu de QuébecCentre hospitalier de l'Université Laval
Fundersnot available
KeywordsBrachytherapyDose rateMedicineProof of conceptMedical physicsComputer scienceRadiologyRadiation therapy

Abstract

fetched live from OpenAlex

Background and Purpose: The addition of interstitial needles to intracavitary gynecologic (GYN) high dose rate (HDR) brachytherapy has been shown to improve target coverage and organs-at-risk (OAR) sparing. However, no commercial solution allows real-time guidance of interstitial catheter placement. This phantom study aimed to evaluate the feasibility of an electromagnetic (EM) tracking system guidance workflow for GYN HDR brachytherapy treatment in a magnetic resonance imaging (MRI) and real-time transrectal ultrasound (TRUS) fusion scenario. Materials and Methods: A clinical investigational system combining a treatment planning system and the EM tracking technology was used. The 3D T2 weighted magnetic resonance (MR) image set of a patient treated with intracavitary and interstitial HDR brachytherapy was retrospectively chosen. The MR image set was used to delineate the target and the OARs. A preplan was generated to determine needles positions in advance. The implant was reproduced in a water phantom. A 3D TRUS scan was acquired, and a rigid registration between the MR and the TRUS images was performed. Results: The accuracy of the EM tracking system was < 1 mm for both the sagittal and the transverse modes of the TRUS probe. Contours that were delineated on the MRI were propagated on the TRUS images after the rigid registration. Needle insertion was successfully guided in real time with the EM tracking system on the TRUS live image using the MRI contours for guidance. Conclusion: Based on this proof-of-concept, real-time EM-guidance of interstitial needle for GYN HDR brachytherapy appears to be feasible.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.319
Teacher spread0.305 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuePhysics and Imaging in Radiation OncologySame topicEndometrial and Cervical Cancer TreatmentsFrench-language works237,207