MétaCan
Menu
Back to cohort
Record W4403806792 · doi:10.1111/jon.13247

Continuous transcranial ultrasound in large vessel stroke: Image guidance for high‐intensity focused sonothrombolysis

2024· article· en· W4403806792 on OpenAlexaff
Ann‐Marie Beaudoin, Caroline Cayer, M. Sirois, Patrice Masson, Nicolas Quaegebeur, Marie‐Claude Battista, Samuel Lemaire‐Paquette, Marie‐Pierre Lapointe‐Garant, F. Moreau

Bibliographic record

VenueJournal of Neuroimaging · 2024
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsCentre Intégré Universitaire de Santé et de Services Sociaux du Saguenay–Lac-Saint-JeanCentre Intégré Universitaire de Santé et de Services Sociaux du Centre-Sud-de-l'Île-de-MontréalCentre Hospitalier Universitaire de SherbrookeUniversité de Sherbrooke
Fundersnot available
KeywordsMedicineRadiologyOcclusionStroke (engine)UltrasoundContrast-enhanced ultrasoundInterquartile rangeTranscranial DopplerThrombusHigh-intensity focused ultrasoundSurgery

Abstract

fetched live from OpenAlex

BACKGROUND AND PURPOSE: Sonothrombolysis is a potential adjunctive therapy for large vessel occlusion (LVO) stroke. Bedside ultrasound image-guided high-intensity focused ultrasound (HIFU) therapy could deliver higher energy therapeutic ultrasound to the thrombus with higher precision than what was previously accomplished in human trials. The aim is to test the feasibility of diagnostic transcranial contrast-enhanced ultrasound (CEUS) to image the occlusion site and continuously maintain the guidance image on-target for a sufficient exposure time for HIFU to be effective during LVO stroke evaluation and treatment. METHODS: This prospective, single center, observational cohort study included adult patients, presenting within 6 hours of stroke symptom onset, with LVO identified on computed tomography angiography (CTA). A hand-held CEUS imaging study was initiated following CTA and lasted up to 30 minutes. The primary outcome is the proportion of patients where a guidance CEUS image of the occlusion was achieved. RESULTS: A CEUS image of the occluded artery was obtained in 32/35 of the included patients. The median total imaging time was 23 minutes (interquartile range 15-30). Patients undergoing thrombectomy had a lower total imaging time (17 vs. 29.5 minutes, p = .002). When imaging was successful, on-target image was maintained for only 58% (standard deviation 23.8%) of total imaging time. No complications related to CEUS were observed. CONCLUSIONS: This feasibility study explored the use of diagnostic transcranial CEUS for continuous imaging of occlusion sites in LVO strokes. Challenges in maintaining target image during HIFU were identified, highlighting the need for technical advances for clinical application.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.731
Threshold uncertainty score0.633

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.237
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of NeuroimagingSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207