MétaCan
Menu
Back to cohort
Record W4403960027 · doi:10.1016/j.jacep.2024.09.003

Long-Term Differences in Autonomic Alterations After Cryoballoon vs Radiofrequency Atrial Fibrillation Ablation

2024· article· en· W4403960027 on OpenAlexaff
Jason G. Andrade, Richard G. Bennett, Marc W. Deyell, M. Bennett, Jobanjit Phulka, Nathaniel M. Hawkins, Tolga Aksu, Thalia S. Field, Martín Aguilar, Paul Khairy, Laurent Macle

Bibliographic record

VenueJACC. Clinical electrophysiology · 2024
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsUniversité de MontréalUniversity of British ColumbiaBC Innovation CouncilVancouver General HospitalMontreal Heart Institute
Fundersnot available
KeywordsAtrial fibrillationCardiologyMedicineInternal medicineRadiofrequency ablationTerm (time)Ablation

Abstract

fetched live from OpenAlex

BACKGROUND: The long-term natural history of autonomic alterations following catheter ablation of drug-refractory paroxysmal atrial fibrillation is poorly defined. OBJECTIVES: The authors sought to define the long-term impact of thermal catheter ablation on the cardiac autonomic system. METHODS: The study included 346 patients with drug-refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using thermal ablation energy (radiofrequency or cryoballoon ablation). All patients underwent insertion of a Reveal LINQ implantable cardiac monitor prior to ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (HRV) (measured as the standard deviation of the average normal-to-normal), daytime heart rate, and nighttime heart rate (NHR). Longitudinal autonomic data in the 2-month period prior to the date of ablation were compared with the 3 years following ablation. RESULTS: Following ablation, there was a significant decrease in HRV (10-20 ms; P < 0.0001) and significant increases in daytime heart rate and NHR (10 beats/min [P < 0.0001] and 7 beats/min [P < 0.0001], respectively). Changes in autonomic parameters were greatest in the first 3 months following ablation but remained significantly different from baseline for 36 months following ablation. Greater changes in NHR and HRV were associated with improved freedom from recurrent arrhythmia. The type of thermal ablation energy had no influence on the heart rate and autonomic parameters. CONCLUSIONS: Pulmonary vein isolation using thermal ablation energy results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are independent of the ablation technology employed and are associated with procedural success. (Cryoballoon vs Irrigated Radiofrequency Catheter Ablation: Double Short vs Standard Exposure Duration [CIRCA-DOSE]; NCT01913522).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.045
Threshold uncertainty score0.737

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.380
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJACC. Clinical electrophysiologySame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207