A Dual Column pH Switchable Water Stationary Phase System for Separation Control in Supercritical Fluid Chromatography
Bibliographic record
Abstract
ABSTRACT A dual column system comprised of a pH switchable water stationary phase column and a conventional non‐polar capillary column is introduced for use in Supercritical Fluid Chromatography (SFC). By removing or adding NH4OH to the system hydration source, the water stationary phase pH can be rapidly switched between acidic (measured at pH∼3) and basic (measured at pH∼9) in seconds, while the operating character of the conventional column is unchanged. This switch modulates the velocity of ionizable analytes about 20‐fold in the system, whereas non‐ionizable analytes are not affected. In this way, the retention time of acids and/or bases can be reproducibly altered (<1% RSD; n = 3) in SFC separations. As a result, analyte selectivity and resolution can be readily controlled during analyses. For example, a selectivity reversal (alpha from 0.4 to 1.6) and a resolution increase (from 0 to 13) are demonstrated. Rapid stationary phase pH switching also allows multiple acids, bases, and/or neutral analytes to be determined simultaneously. Applications demonstrate that this method can greatly simplify complex mixture analysis in SFC by helping to separate target analytes from interfering matrix components.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".