Biodegradable stimulating electrodes for resident neural stem cell activation in vivo
Bibliographic record
Abstract
Brain stimulation has been recognized as a clinically effective strategy for treating neurological disorders. Endogenous brain neural precursor cells (NPCs) have been shown to be electrosensitive cells that respond to electrical stimulation by expanding in number, undergoing directed cathodal migration, and differentiating into neural phenotypes in vivo, supporting the application of electrical stimulation to promote neural repair. In this study, we present the design of a flexible and biodegradable brain stimulation electrode for temporally regulated neuromodulation of NPCs. Leveraging the cathodally skewed electrochemical window of molybdenum and the volumetric charge transfer properties of conductive polymer, we engineered the electrodes with high charge injection capacity for the delivery of biphasic monopolar stimulation. We demonstrate that the electrodes are biocompatible and can deliver an electric field sufficient for NPC activation for 7 days post implantation before undergoing resorption in physiological conditions, thereby eliminating the need for surgical extraction. The biodegradable electrode demonstrated its potential to be used for NPC-based neural repair strategies.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".