Evaluation of a Commercially Available Radiochromic Film for Use as a Complementary Dosimeter for Rapid In-field Low Photon Equivalent Radiation Dose (≤50 mSv) Monitoring
Bibliographic record
Abstract
ABSTRACT: This work investigates the low photon radiation dose (≤50 mSv) response of commercially available radiochromic films as a potential field dosimeter that could be used by the Canadian Armed Forces to complement their existing personal radiation dosimeters. The films were exposed to various photon energies from x-ray devices and radioisotopes (cesium-137, cobalt-60, and americium-241), and their radiation signal was read using three methods: net optical density, UV/visible spectroscopy, and Fourier transform infrared spectroscopy. A complimentary film dosimeter for field usage should, for military use, display a visual color change and detect doses ≤50 mSv. Given the film's radiochromic properties, it was determined that the net optical density method was the most optimal read-out method, which ascertained a minimum detection dose limit of 4.5 mSv under exposure to a clinical orthovoltage operated at 100 kVp. The film presented an overall linear relationship between net optical density and radiation dose; however, they also portrayed a photon energy-dependent response between 0-100 mSv. Overall, the radiochromic films presented a real-time visual dose signal that could be interpreted rapidly in a mobile laboratory and possessed the ability to detect photon doses ≤50 mSv below the vendor's recommended limits, making it a suitable option as a complementary, disposable, military dosimetric tool. Future work includes the investigation of the film's response under multi- and unknown source environments and environmental-dependent factors such as UV/sunlight exposure and extreme temperatures.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".