MétaCan
Menu
Back to cohort
Record W4404894018 · doi:10.1186/s42490-024-00086-w

A performance evaluation of commercially available and 3D-printable prosthetic hands: a comparison using the anthropomorphic hand assessment protocol

2024· article· en· W4404894018 on OpenAlexaff
Joshua R. Siegel, A.C.K. Lau, Dylan J. A. Brenneis, Michael R. Dawson, Patrick M. Pilarski, Jonathon S. Schofield

Bibliographic record

VenueBMC Biomedical Engineering · 2024
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversity of Alberta
FundersUniversity of California, DavisUniversity of California
Keywords3d printedProtocol (science)3D printingComputer scienceProsthetic handGRASPBiomedical engineeringEngineeringSoftware engineeringMedicineArtificial intelligenceMechanical engineering

Abstract

fetched live from OpenAlex

Despite significant technological progress in prosthetic hands, a device with functionality akin to a biological extremity is far from realization. To better support the development of next-generation technologies, we investigated the grasping capabilities of clinically prescribable and commercially available (CPCA) prosthetic hands against those that are 3D-printed, which offer cost-effective and customizable solutions. Our investigation utilized the Anthropomorphic Hand Assessment Protocol (AHAP) as a benchtop evaluation of the multi-grasp performance of 3D-printed devices against CPCA prosthetic hands. Our comparison sample included three open-source 3D-printed prosthetic hands (HACKberry Hand, HANDi Hand, and BEAR PAW) and three CPCA prosthetic hands (Össur i-Limb Quantum, RSL Steeper BeBionic Hand V3, and Psyonic Ability Hand), along with including previously published AHAP data for four additional 3D-printed hands (Dextrus v2.0, IMMA, InMoov, and Limbitless). Our findings revealed a notable grasping performance disparity, with 3D-printed prostheses generally underperforming compared to their CPCA counterparts, specifically in cylindrical, diagonal volar, extension, and spherical grips. We propose that the observed performance shortfalls are likely attributed to the design or build quality of the 3D-printed prostheses, owing to the fact that 3D-printed hands often have a lower technology readiness level for widespread use. Addressing the limitations highlighted in this work and subsequent research will play a crucial role in refining the design and functionality of both 3D-printed and CPCA prosthetic devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.612
Threshold uncertainty score0.446

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.320
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueBMC Biomedical EngineeringSame topicMuscle activation and electromyography studiesFrench-language works237,207