MétaCan
Menu
Back to cohort
Record W4404936882 · doi:10.1101/2024.11.29.24318211

Methods for analytical validation of novel digital clinical measures: A simulation study

2024· preprint· en· W4404936882 on OpenAlexaff
Simon Turner, Chen Chen, Rolando Acosta, Eric Fernando Boeck Daza, Lysbeth Floden, John Langford, Leif Simmatis, Berend Terluin, Piper Fromy, Piper Fromy

Bibliographic record

VenuemedRxiv · 2024
Typepreprint
Languageen
FieldMathematics
TopicStatistical Methods in Clinical Trials
Canadian institutionsUniversity of Toronto
FundersArnold Ventures
KeywordsComputer scienceModel validationReliability engineeringData scienceEngineering

Abstract

fetched live from OpenAlex

Analytical validation is a crucial step in the evaluation of algorithms that process data from sensor-based digital health technologies (sDHTs). Analytical validation of novel digital measures can be complicated when reference measures with directly comparable units are not available. To address this, we conducted a simulation study. Data was simulated assuming a latent physical ability trait, indirectly accessed through an sDHT-derived target measure collecting step count data, and the items of a clinical outcome assessment (COA) measuring self-reported physical activity. We quantified the ability of two methods to assess the latent relationship between reference and target measures: the Pearson Correlation Coefficient (PCC) and factor correlations from a two-factor confirmatory factor analysis (CFA) model. Additionally, three multiple linear regression models were used to evaluate if multiple COA reference measures can more completely represent a target measure of interest. Our findings show that PCC was more stable, easier to compute, and relatively robust with respect to violations of parametric assumptions than CFA, particularly with small sample sizes. However, CFA was less biased than PCC in all scenarios investigated. We demonstrate that using both PCC and CFA generates more confidence in the results of a target and reference measure comparison. Finally, regression results suggest that incorporating multiple reference measures with more frequent collection time points can provide a more complete presentation of the sDHT's analytical validity. Novel digital measures are being developed at an accelerating pace and promise to revolutionize patient care and medical product development. Our findings provide investigators with crucial information for choosing appropriate methods to perform rigorous analytical validation of these novel measures, including an open-access simulation toolkit.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.061
metaresearch head score (Gemma)0.181
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: Methods · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.939
Threshold uncertainty score0.325

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0610.181
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0010.002
Open science0.0020.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.845
GPT teacher head0.707
Teacher spread0.138 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

Study designSimulation or modeling
DomainMethods
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes1
Has abstractyes

Explore more

Same venuemedRxivSame topicStatistical Methods in Clinical TrialsFrench-language works237,207