MétaCan
Menu
Back to cohort
Record W4404956342 · doi:10.14740/jh1337

Optimizing Falling Drop Hemoglobin Method by Comparing Capillary Versus Venous Blood and Determining the Stability of the Copper Sulfate Solution

2024· article· en· W4404956342 on OpenAlexvenueno aff
Amogh Chariyamane, Tim R Randolph

Bibliographic record

VenueJournal of Hematology · 2024
Typearticle
Languageen
FieldMedicine
TopicIron Metabolism and Disorders
Canadian institutionsnot available
Fundersnot available
KeywordsHemoglobinCopper sulfateDrop (telecommunication)MedicineCopperCapillary actionVenous bloodFalling (accident)SulfateInternal medicineMaterials scienceMetallurgyComposite material

Abstract

fetched live from OpenAlex

Background: Anemia is a global health issue that affects over 1 billion people and contributes to maternal mortality and birth defects. Low-resource, tropical areas face a dual challenge: high prevalence of anemia and inability to access affordable testing methods. The falling drop hemoglobin method has been developed by our lab to quantify hemoglobin concentration and assess anemia by timing the descent of venous blood in a column of copper sulfate solution, without using electricity or batteries. This research aimed to optimize the falling drop hemoglobin method by evaluating the use of capillary blood to reduce within sample variance and assessing copper sulfate stability to determine shelf life in expected working conditions. Methods: The falling drop hemoglobin method was performed on both venous and capillary blood samples collected directly from the fingertip by dispensing 44 µL of blood in a copper sulfate column. A microhematocrit was performed on the venous blood sample and converted mathematically to a hemoglobin level to serve as the standard. Copper sulfate stability was assessed for 32 weeks among three solutions: solution prepared fresh on day of testing, solution incubated at room temperature, and solution incubated at 37.7 °C. Results: Capillary blood yielded higher average descent times and higher standard deviations than venous blood. Collecting precisely 44 µL of capillary blood proved challenging and impractical. In copper sulfate stability testing, freshly prepared solution yielded the highest average descent time. A one-way analysis of variance (ANOVA) test and Tukey's honestly significant difference (HSD) post hoc testing revealed no significant difference between mean descent times of freshly prepared and 37.7 °C solutions (P = 0.26) and between room temperature and 37.7 °C solutions (P = 0.64), but a significant difference between freshly prepared and room temperature solutions (P = 0.04). Conclusions: This study found that capillary blood did not present a more accurate alternative to venous blood in the falling drop hemoglobin test, and copper sulfate did not degrade over 32 weeks at 37.7 °C. This lends support for the current use of venous blood in the test, and for use of copper sulfate solution in tropical climates, where the test is most necessary, with a shelf life of at least 32 weeks.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.266
Threshold uncertainty score0.243

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.300
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueJournal of HematologySame topicIron Metabolism and DisordersFrench-language works237,207