Abstract
Drug-coated balloon (DCB) catheters offer an alternative to drug-eluting stents (DES) by delivering anti-proliferative drugs directly to vessel walls, avoiding implantation of a permanent metallic structure. While DCBs have shown efficacy for in-stent restenosis, evidence for their application in de novo coronary disease and chronic total occlusion (CTO) PCI is growing. We present a case of a 49-year-old male with multivessel chronic total and subtotal occlusions who had complete percutaneous revascularisation using a DCB only strategy. Each lesion had unique characteristics involving its length and location, bifurcation anatomy, and vessel diameter for which this stent-free approach was favored. DCB use in CTO PCI may be promising in select cases and lesions, and further studies are warranted to ascertain long-term efficacy in this setting.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".