MétaCan
Menu
Back to cohort
Record W4404970538 · doi:10.1111/echo.70047

Core Laboratory Versus Center‐Reported Echocardiographic Assessment of the Native and Bioprosthetic Aortic Valve

2024· article· en· W4404970538 on OpenAlexaff
Bart J.J. Velders, Michiel D. Vriesendorp, Neil J. Weissman, Joseph F. Sabik, Michael J. Reardon, François Dagenais, Michael G. Moront, Vivek Rao, Shinichi Fukuhara, Ralf Günzinger, Wouter J. van Leeuwen, W. Morris Brown, Rolf H. H. Groenwold, Robert J.M. Klautz, Federico M. Asch

Bibliographic record

VenueEchocardiography · 2024
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsToronto General Hospital
FundersMedtronic
KeywordsMedicineCardiologyAortic valveInternal medicineAortic valve replacementIntraclass correlationVentricular outflow tractRegurgitation (circulation)StenosisAortic valve stenosisConfidence intervalProsthesisStroke volumeSurgeryHeart rateBlood pressure

Abstract

fetched live from OpenAlex

BACKGROUND: Insights into quantitative differences between core laboratory and center-reported echocardiographic assessment of the native and bioprosthetic aortic valve are lacking. We aimed to explore clinically relevant differences between these evaluations. METHODS: Data were used from the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Pivotal Trial for the Avalus valve. In this trial, patients with an indication for surgical aortic valve replacement (SAVR) due to aortic stenosis or regurgitation (AR) were enrolled. Serial echocardiographic examinations were performed at each center and blindly reanalyzed by an independent echocardiographic core laboratory (ECL). For the bioprosthetic valve analysis, postoperative data throughout the 5-year follow-up were pooled. Differences between the ECL and the centers in continuous parameters were quantified in mean differences and intraclass correlation coefficients (ICCs). Agreement on AR, paravalvular leak (PVL), and prosthesis-patient mismatch (PPM) classification was investigated using Cohen's kappa coefficients. RESULTS: The analysis on the native aortic valve was performed on 1118 echocardiograms. The relative mean difference was largest for the left ventricular outflow tract (LVOT) area, followed by stroke volume and effective orifice area (index), with center-reported values being 11%-7% higher. High ICCs of around 0.90 were observed for the parameters peak aortic jet velocity, mean pressure gradient, and the velocity-time integral across the aortic valve. Over 5000 echocardiograms were available for the bioprosthetic valve analysis. Therein, comparable results were observed. The kappa coefficient was 0.59 (95% confidence interval [CI] 0.56, 0.63) for agreement on native AR, 0.28 (95% CI 0.18, 0.37) for PVL, and 0.42 (95% CI 0.40, 0.44) for PPM. CONCLUSIONS: There is high agreement between the ECL and clinical centers on continuous-wave Doppler-related measurements. In contrast, agreement is low for parameters that involve measurement of the LVOT diameter. These results provide important context for the interpretation of aortic valve performance in studies that lack central ECL evaluation. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02088554.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.014
Threshold uncertainty score0.808

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.004
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.355
Teacher spread0.331 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueEchocardiographySame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207