MétaCan
Menu
Back to cohort
Record W4405443661 · doi:10.3390/fluids9120297

Effectiveness in Cooling a Heat Sink in the Presence of a TPMS Porous Structure Comparing Two Different Flow Directions

2024· article· en· W4405443661 on OpenAlexaff
M. Ziad Saghir, M.M. Rahman

Bibliographic record

VenueFluids · 2024
Typearticle
Languageen
FieldEngineering
TopicHeat Transfer Mechanisms
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsHeat sinkSink (geography)Porous mediumPorosityHeat flowFlow (mathematics)MechanicsEnvironmental scienceMaterials scienceProcess engineeringComputer scienceThermodynamicsPetroleum engineeringGeologyPhysicsEngineeringComposite materialThermal

Abstract

fetched live from OpenAlex

The triply periodic minimal surface (TPMS) is receiving much interest among researchers. The advantage of using this TPMS structure is the ability to design a structure based on engineering need. In the present context, experimental measurement was conducted and compared with numerical models using a foam porous medium and TPMS porous structure, leading to an accurate calibration of the model. A porous medium, metal foam, was heated experimentally at the bottom, and forced convection was investigated for different heating conditions. Then, the porous foam was replaced with a TPMS, and the experiment was repeated under similar conditions. The experimental data were compared with the numerical model using COMSOL software. Besides the model’s accuracy, the TPMS showed a uniform heating condition contrary to the metal foam case. At a later stage, the numerical model was used to investigate the importance of flow direction (two flow directions) in cooling hot surfaces. The first flow was parallel to the hot surface, and the second perpendicular to the hot surface. The TPMS structure was located on the top of the hot surface and acted as a fin in both cases. The Nusselt number exceeded 80 in the presence of the TPMS. As the porosity of the TPMS decreases below 0.7, a more considerable pressure drop is observed. The performance evaluation criterion was found to be greater than 70 when the porosity of the TPMS structure was 0.8.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.242
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueFluidsSame topicHeat Transfer MechanismsFrench-language works237,207