MétaCan
Menu
Back to cohort
Record W4405466521 · doi:10.1088/2632-2153/ada087

Automation of quantum dot measurement analysis via explainable machine learning

2024· article· en· W4405466521 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueMachine Learning Science and Technology · 2024
Typearticle
Languageen
FieldComputer Science
TopicExplainable Artificial Intelligence (XAI)
Canadian institutionsnot available
FundersArmy Research OfficeNational Science Foundation
KeywordsAutomationQuantum dotComputer scienceArtificial intelligenceEngineeringPhysicsOptoelectronicsMechanical engineering

Abstract

fetched live from OpenAlex

Abstract The rapid development of quantum dot (QD) devices for quantum computing has necessitated more efficient and automated methods for device characterization and tuning. Many of the measurements acquired during the tuning process come in the form of images that need to be properly analyzed to guide the subsequent tuning steps. By design, features present in such images capture certain behaviors or states of the measured QD devices. When considered carefully, such features can aid the control and calibration of QD devices. An important example of such images are so-called triangle plots , which visually represent current flow and reveal characteristics important for QD device calibration. While image-based classification tools, such as convolutional neural networks (CNNs), can be used to verify whether a given measurement is good and thus warrants the initiation of the next phase of tuning, they do not provide any insights into how the device should be adjusted in the case of bad images. This is because CNNs sacrifice prediction and model intelligibility for high accuracy. To ameliorate this trade-off, a recent study introduced an image vectorization approach that relies on the Gabor wavelet transform (Schug et al 2024 Proc. XAI4Sci: Explainable Machine Learning for Sciences Workshop (AAAI 2024) (Vancouver, Canada) pp 1–6). Here we propose an alternative vectorization method that involves mathematical modeling of synthetic triangles to mimic the experimental data. Using explainable boosting machines, we show that this new method offers superior explainability of model prediction without sacrificing accuracy. This work demonstrates the feasibility and advantages of applying explainable machine learning techniques to the analysis of QD measurements, paving the way for further advances in automated and transparent QD device tuning.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.921
Threshold uncertainty score0.762

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0030.011
Science and technology studies0.0010.001
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.265
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it