MétaCan
Menu
Back to cohort
Record W4405700603 · doi:10.1186/s12891-024-08174-7

Efficacy and safety of low-intensity ultrasound therapy for myofascial pain syndrome: a systematic review and meta-analysis

2024· review· en· W4405700603 on OpenAlexfundno aff
Xize Li, Yijun Lin, Peijue He, Qian Wang

Bibliographic record

VenueBMC Musculoskeletal Disorders · 2024
Typereview
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicMyofascial pain diagnosis and treatment
Canadian institutionsnot available
FundersMcMaster University
KeywordsMedicineTherapeutic ultrasoundMeta-analysisSports medicineMyofascial pain syndromeUltrasoundPhysical therapyPlaceboIntensity (physics)Systematic reviewClinical trialAdverse effectRandomized controlled trialInternal medicineMEDLINERadiologyPathologyAlternative medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Myofascial Pain Syndrome (MPS) is a common pain disorder characterized by the presence of trigger points within the muscles or fascia. Low-intensity ultrasound therapy, as a noninvasive modality, has indeed found application in the management of MPS, but its efficacy for myofascial pain syndrome has still been controversial. The objective of this systematic review was to assess the safety and efficacy of low-intensity ultrasound therapy for MPS. METHODS: We searched PubMed, Embase, PEDro, Web of Science, and CENTRAL for RCTs on ultrasound therapy in MPS patients. We included RCTs comparing ultrasound with other therapies or placebo-sham ultrasound. Clinical outcomes included pain scores and physical functional performance. Risk of bias and heterogeneity were assessed. Two authors of the review independently evaluated the risk of bias of each trial and extracted the data. RESULTS: = 91%). Patients receiving low-intensity ultrasound had improved on pressure pain threshold. Compared with other treatments, there were no differences in outcomes functional scores. CONCLUSIONS: The current study indicates that low-intensity ultrasound effectively reduces pain intensity in MPS patients. The heterogeneity regarding the parameters of ultrasound, including frequency, intensity, time was found to be high among the included studies. Each therapeutic modality works differently in various situations and may lead to multitudinous effects. The positive impact of low-intensity ultrasound on functional improvement needs to be further analyzed through more high-quality clinical trials with large sample sizes in the future. TRIAL REGISTRATION: This study was registered on the following website: https://www.crd.york.ac.uk/PROSPERO/ . The PROSPERO registered ID is CRD42023472032.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.013
metaresearch head score (Gemma)0.035
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.019
Threshold uncertainty score0.069

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0130.035
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0190.028
Bibliometrics0.0050.006
Science and technology studies0.0010.001
Scholarly communication0.0030.002
Open science0.0020.001
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0050.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.027
GPT teacher head0.321
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueBMC Musculoskeletal DisordersSame topicMyofascial pain diagnosis and treatmentFrench-language works237,207