MétaCan
Menu
Back to cohort
Record W4406045835 · doi:10.1088/1361-6560/ada5a3

Dual-modality flow phantom for ultrasound and optical flow measurements

2025· article· en· W4406045835 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenuePhysics in Medicine and Biology · 2025
Typearticle
Languageen
FieldEngineering
TopicFlow Measurement and Analysis
Canadian institutionsUniversity of WaterlooResearch Institute for Aging
FundersCanadian Institutes of Health ResearchE.W.R. Steacie Memorial Fund
KeywordsImaging phantomModality (human–computer interaction)Flow (mathematics)Optical flowUltrasoundMedical physicsComputer scienceOpticsComputer visionAcousticsPhysicsArtificial intelligenceMechanicsImage (mathematics)

Abstract

fetched live from OpenAlex

Abstract As ultrasound-compatible flow phantoms are devised for performance testing and calibration, there is a practical need to obtain independent flow measurements for validation using a gold-standard technique such as particle image velocimetry (PIV). In this paper, we present the design of a new dual-modality flow phantom that allows ultrasound and PIV measurements to be simultaneously performed. Our phantom’s tissue mimicking material is based on a novel hydrogel formula that uses propylene glycol to lower the freezing temperature of an ultrasound-compatible poly(vinyl) alcohol cryogel and, in turn, maintain the solution’s optical transparency after thermocycling. The hydrogel’s optical attenuation {1.56 dB cm −1 with 95% confidence interval (CI) of [1.512 1.608]}, refractive index {1.337, CI: [1.340 1.333]}, acoustic attenuation {0.038 dB/(cm × MHz b ), CI: [0.0368 0.0403]; frequency dependent factor of 1.321, CI: [1.296 1.346]}, and speed of sound {1523.6 m s −1 , CI: [1523.8 1523.4]} were found to be suitable for PIV and ultrasound flow measurements. As an application demonstration, a bimodal flow phantom with spiral lumen was fabricated and used in simultaneous flow measurements with PIV and ultrasound color flow imaging (CFI). Velocity fields and profiles were compared between the two modalities under a constant flow rate (2.5 ml s −1 ). CFI was found to overestimate flow speed compared to the PIV measurements, with a 14%, 10%, and 6% difference between PIV and ultrasound for the 60°, 45°, and 30° angles measured. These results demonstrate the new phantom’s feasibility in enabling performance validation of ultrasound flow mapping tools.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.604
Threshold uncertainty score0.377

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.192
GPT teacher head0.363
Teacher spread0.172 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it