MétaCan
Menu
Back to cohort
Record W4406475398 · doi:10.1186/s13089-025-00405-9

A novel “lateral approach short axis in-plane” technique vs. conventional “short-axis out-of-plane approach” for ultrasound-guided internal jugular vein access: a prospective randomized non-inferiority trial

2025· article· en· W4406475398 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueThe Ultrasound Journal · 2025
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsDalhousie University
Fundersnot available
KeywordsMedicineUltrasoundInterventional radiologyRandomized controlled trialInternal jugular veinRadiologyJugular veinPlane (geometry)Medical physicsSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The cannulation of the internal jugular vein (IJV) is a frequent procedure in critically ill patients. According to the guidelines, real-time ultrasound navigation is recommended. Traditional techniques pose several disadvantages, such as suboptimal needle visualization. Therefore, this non-inferiority trial aimed to describe the novel approach and compare the novel lateral in-plane short-axis approach for IJV access with the conventional short-axis out-of-plane approach. OBJECTIVES: The primary objective of the trial was to prove that the first attempt success rate in the novel technique is non-inferior to the conventional technique. The secondary objectives were to demonstrate that the complication rate and the functional duration of the catheter in the novel technique are not inferior to those in the conventional technique. METHODS: Patients eligible for IJV cannulation were randomly assigned to either the novel technique (Group A) or the conventional one (Group B). The procedure duration, success rate and the number of attempts required were documented. The functionality of the catheter and complications were monitored from insertion until the catheter removal. Standard descriptive statistical methods were employed for the analysis. RESULTS: A total of 200 subjects were equally divided between Group A and Group B. For the primary outcome, there was no significant difference in first attempt success rate (Group A: 79, Group B: 77, p = 0.434). Secondary outcomes, including complications and catheter functional time, did not differ significantly between the groups. However, the novel technique demonstrated a significantly faster procedure time (Group A: 315 s, Group B: 330 s, p = 0.016). Notably, the novel approach was linked with significantly larger IJV diameter measured during the procedure (Group A: 18.2 mm, Group B: 12.1 mm, p < 0.001). CONCLUSION: The novel lateral in-plane short-axis approach for IJV cannulation is a non-inferior alternative with a lower incidence of posterior vessel wall puncture compared to the conventional approach.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.468
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0080.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.371
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it