MétaCan
Menu
← Back to cohort
Record W4406861166 · doi:10.1371/journal.pone.0318218

Comparison of behind-the-ear vs. off-the-ear speech processors in cochlear implants: A systematic review and narrative synthesis

2025· review· en· W4406861166 on OpenAlexaboutno aff
Muhammed Ayas, Jameel Muzaffar, Veronica Phillips, Manohar Bance

Bibliographic record

VenuePLoS ONE · 2025
Typereview
Languageen
FieldNeuroscience
TopicHearing Loss and Rehabilitation
Canadian institutionsnot available
FundersNIHR Cambridge Biomedical Research CentreNational Institute for Health and Care Research
KeywordsAudiologySpeech perceptionCochlear implantCochrane LibraryMedicineMEDLINEHearing lossSystematic reviewHearing aidQUIETPerceptionPsychologyMeta-analysis

Abstract

fetched live from OpenAlex

BACKGROUND: Cochlear implants (CI) with off-the-ear (OTE) and behind-the-ear (BTE) speech processors differ in user experience and audiological performance, impacting speech perception, comfort, and satisfaction. OBJECTIVES: This systematic review explores audiological outcomes (speech perception in quiet and noise) and non-audiological factors (device handling, comfort, cosmetics, overall satisfaction) of OTE and BTE speech processors in CI recipients. METHODS: We conducted a systematic review following PRISMA-S guidelines, examining Medline, Embase, Cochrane Library, Scopus, and ProQuest Dissertations and Theses. Data encompassed recipient characteristics, processor usage, speech perception, and non-audiological factors. Studies were assessed for quality and risk of bias by using Newcastle-Ottawa Scale (NOS). RESULTS: Nine studies involving 204 CI recipients, with a mean age of 49.01 years and 6.62 years of processor use, were included. Audiological results indicated comparable performance in quiet environments, with a slight preference for OTE in noisy conditions. For non-audiological factors, OTE processors excelled in comfort, handling, and aesthetics, leading to higher satisfaction. More data on medical complications and long-term implications is needed. CONCLUSION: OTE processors may offer comparable performance to BTE processors in certain conditions, though not universally across all audiological outcomes. Interpretation depends on settings, processor generation, and testing paradigms. However, non-audiological factors might favour OTE. Understanding current literature may guide professionals in selecting suitable processors for CI recipients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.037
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.010
Threshold uncertainty score0.048

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.037
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0100.009
Bibliometrics0.0080.008
Science and technology studies0.0010.001
Scholarly communication0.0040.003
Open science0.0020.002
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.111
GPT teacher head0.367
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venuePLoS ONE→Same topicHearing Loss and Rehabilitation→French-language works237,207→