MétaCan
Menu
Back to cohort
Record W4407407537 · doi:10.1097/hjh.0000000000003965

Blood pressure measurement at kiosks in public spaces: systematic review and consensus statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability endorsed by the International Society of Hypertension and the World Hypertension League

2025· review· en· W4407407537 on OpenAlexaff
George S. Stergiou, Konstantinos G. Kyriakoulis, Αναστάσιος Κόλλιας, Richard J. McManus, Ariadni Menti, Gianfranco Parati, Aletta E. Schutte, Ji-Guang Wang, Kei Asayama, Roland Asmar, Grzegorz Bilo, Niamh Chapman, Takeshi Fujiwara, Geoffrey A. Head, Kazuomi Kario, Yan Li, Efstathios Manios, Dimitrios Mariglis, Anastasia S. Mihailidou, Paul Muntner, Martin G. Myers, Teemu Niiranen, Takayoshi Ohkubo, Stefano Omboni, Francesca Saladini, James E. Sharman, Daichi Shimbo, Alejandro de la Sierra, Paolo Palatini

Bibliographic record

VenueJournal of Hypertension · 2025
Typereview
Languageen
FieldMedicine
TopicBlood Pressure and Hypertension Studies
Canadian institutionsUniversity of TorontoSunnybrook Health Science CentreHealth Sciences CentreUniversity of British Columbia
Fundersnot available
KeywordsMedicineInteractive kioskBlood pressureContext (archaeology)Systematic reviewObservational studyMEDLINEInternal medicineComputer science

Abstract

fetched live from OpenAlex

Kiosk devices for unsupervised self-measurement of blood pressure (BP) are being used in public spaces and healthcare settings in several countries. This statement by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability provides a review of the published evidence on kiosk BP devices and consensus recommendations for their requirements and clinical use. A systematic literature search identified 54 relevant studies. Kiosk BP measurements appeared to be close to office BP [mean difference systolic 0.2 mmHg (95% confidence intervals -1.3 to 1.8); diastolic -0.4 mmHg (-3.5 to 2.7)], and higher than daytime ambulatory and home BP [mean difference 6.0 mmHg (1.6-10.4)/5.0 (2-8) and 8.1 mmHg (-2.6 to 18.9)/0.2 (-9.6 to 10.0), respectively]. Randomized or observational studies using kiosk BP measurements for hypertension screening or for assessing hypertension control were also included, as well as studies investigating users' and healthcare professionals' opinions, acceptability, and perspectives regarding kiosk BP measurements, and validation studies of kiosk BP devices. These studies had considerable heterogeneity in design, setting, methodology, measurement protocol, and sample size. Thus, at present, the clinical utility of kiosk BP measurements is uncertain. This ESH consensus statement acknowledges the potential of kiosk BP measurement as an emerging method for unsupervised self-measurement in the context of opportunistic screening for hypertension in apparently healthy people and the long-term monitoring of people with diagnosed hypertension. Requirements for the design, validation, function, and use of kiosk BP monitors are provided, together with the pending research questions on their optimal implementation in clinical practice.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.021
metaresearch head score (Gemma)0.072
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.021
Threshold uncertainty score0.112

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0210.072
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0100.011
Bibliometrics0.0110.013
Science and technology studies0.0010.001
Scholarly communication0.0030.003
Open science0.0020.002
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.095
GPT teacher head0.273
Teacher spread0.178 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of HypertensionSame topicBlood Pressure and Hypertension StudiesFrench-language works237,207