Leadless Ultrasound-Based Cardiac Resynchronization System in Heart Failure Results from the SOLVE-CRT Randomised Sub-study

2025· article· en· W4407749933 on OpenAlexaff
Elisabetta Montemerlo, Giovanni Rovaris, Jagmeet Singh, Christopher A. Rinaldi, Prashanthan Sanders, Spencer H. Kubo, Simon James, Imran Khan Niazi, Timothy R. Betts, Emad F. Aziz, Mauro Biffi, Amir Zaidi, Jeffrey Alison, Angelo Auricchio, Michael R. Gold, JoAnn Lindenfeld, Mary Norine Walsh, Christian Butter

Bibliographic record

VenueEuropean Heart Journal Supplements · 2025
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSt. Thomas Hospital
Fundersnot available
KeywordsMedicineCardiac resynchronization therapyHeart failureCardiologyInternal medicineUltrasoundCardiac UltrasoundRadiologyEjection fraction

Abstract

fetched live from OpenAlex

Abstract Background Despite the well-established role of CRT in heart failure, major limitations of CRT are an occasional incidence of unsuccessful coronary sinus (CS) lead placement, one third non-responders in conventional CRT patients and higher complications risk in CRT upgrade procedures. The WiSE® Wireless Stimulation Endocardial) CRT System is designed to overcome these limitations. Prior non-randomised studies with the WiSE® CRT System have shown high implant success rates and improvement in LV remodeling and heart failure symptoms. Objectives Pivotal study to assess the safety and effectiveness of the WiSE® CRT System in an international, randomized, two-arm, double blinded, prospective study (randomized part only). Method 99 Patients with indication for CRT and previously failed CRT implant, considered as high-risk upgrade to conventional CRT, or non-responders to conventional CRT underwent device implantation and were then randomised into treatment (47 pts, System ON) and control (52 pts System OFF) groups for 6 months. Primary efficacy endpoints were change in LVESV, LVEDV, LVEF and QRS over 6 months in blinded Echo and ECG core lab analysis. Results Mean ΔLVESV (%) -14.6 (-19.6, -9.6); mean ΔLVEDV (%) -8.1 (-11.9, -4.3) and mean ΔQRS (ms) -41.9 (-50.1, -33.7) in the treatment group were significantly lower/shorter than mean ΔLVESV (%) -5.2 (-10.7, 0.2); mean ΔLVEDV (%) -3.0 (-7.0, 1.0) and mean ΔQRS (ms) -1.7 (-7.1,3.8) in the control group, p=0.005; p=0.027 and p=0.001, 95% CI. Mean ΔLVEF (%) 5.4 (3.2, 7.7) in the treatment group increased significantly compared to control group ΔLVEF (%) 2.4 (0.2, 4.5), p=0.048. 8 of 99 pts were attempted from WiSE CRT implant. Conclusion This randomized sub-study of the pivotal SOLVE-CRT trial demonstrates that leadless, ultrasound-based endocardial pacing for heart failure is feasible and efficacious showing evidence of left ventricular remodelling and electrical response after 6 months.Figure 1WISE® CRT System Figure 2Efficacy entire randomised population

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.087
Threshold uncertainty score0.744

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0010.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.299
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Heart Journal SupplementsSame topicCardiac pacing and defibrillation studiesFrench-language works237,207