MétaCan
Menu
Back to cohort
Record W4407771591 · doi:10.1186/s41181-025-00332-z

Ac-225 radiochemistry through the lens of [225Ac]Ac-DOTA-TATE

2025· article· en· W4407771591 on OpenAlexaff
Eline Hooijman, J. R. de Jong, Carolline Ntihabose, Frank Bruchertseifer, Aliyah Morgenstern, Yann Seimbille, Tessa Brabander, Stijn L.W. Koolen, Erik de Blois

Bibliographic record

VenueEJNMMI Radiopharmacy and Chemistry · 2025
Typearticle
Languageen
FieldMedicine
TopicRadiopharmaceutical Chemistry and Applications
Canadian institutionsTRIUMF
FundersErasmus Medisch Centrum
KeywordsChemistryDOTAGentisic acidChelationHistidineMetalHigh-performance liquid chromatographyYield (engineering)ChromatographyRadiochemistryNuclear chemistryPet imagingInorganic chemistryNuclear medicineEnzymeBiochemistry

Abstract

fetched live from OpenAlex

BACKGROUND: Targeted alpha therapy with Ac-225 showed to be effective in treating metastatic cancers. However, the complex decay chain requires optimized radiolabeling and quality control. This study aims to determine critical parameters and establish optimal labeling and accurate measuring techniques for radiochemical yield and purity with DOTA-TATE as a model molecule. Ac-225 sources were analyzed for metals (ΣFe, Zn, Cu) and quantified by UPLC. Optimization of radiolabeling kinetics for clinical conditions was performed in regards to temperature (20-90 °C), heating time (5-60 min), pH (2.5-10, with/without excess of metal ions), buffers, quenchers, volume (0.1-10 mL) and molar activity (90-540 kBq/nmol). The quality control was investigated using radio-TLC/HPLC by changing gradient to evaluate peak separation, radiolysed peptide and impurity separation. RESULTS: Metal ingrowth was observed in Ac-225 stocks (n = 3), (time of arrival: 17.9, 36.8 and 101.4 nmol per 10 MBq). Optimal radiochemical yields were achieved with > 80 °C (20 min) at pH 8.5 (15 mM TRIS) up to 270 kBq. Labeling at a high pH showed a higher RCY, even in presence of an excess of metals. High stability (RCP > 90%) was achieved after addition of quenchers (cysteine, methionine, ascorbate, histidine, or gentisic acid (35 mM)) up to 24 h. For optimal determination of the radiochemical purity (indirect HPLC) fifty fractions are required. CONCLUSION: The quality of Ac-225 labeled DOTA-radiopharmaceuticals is highly dependent on the pH and stabilization (buffer/quencher). Within this research it is demonstrated that optimized quality control methods and accurate measurement of the radiolabeling kinetics are crucial to ensure safe implementation for patient treatment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.332
Teacher spread0.314 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueEJNMMI Radiopharmacy and ChemistrySame topicRadiopharmaceutical Chemistry and ApplicationsFrench-language works237,207