MétaCan
Menu
Back to cohort
Record W4408155944 · doi:10.3390/diagnostics15050615

Accuracy of Velacur in Assessing MASLD and MASH Patients Using Biopsy as the Gold Standard

2025· article· en· W4408155944 on OpenAlexfundno aff
Muhammad Y. Sheikh, N. Hasan, Marwan Almozuaghi, Nadeem Akhtar, Yugjeet Grewal, Caitlin Schneider

Bibliographic record

VenueDiagnostics · 2025
Typearticle
Languageen
FieldMedicine
TopicLiver Disease Diagnosis and Treatment
Canadian institutionsnot available
FundersSonic Incytes
KeywordsGold standard (test)BiopsyMedicineInternal medicine

Abstract

fetched live from OpenAlex

Background/Objectives: VelacurTM is a novel, point-of-care ultrasound device developed to accurately diagnose patients with Metabolic Dysfunction-Associated Steatotic Liver Disease (MASLD) and Metabolic Dysfunction-Associated Steatohepatitis (MASH). The Velacur system non-invasively assesses liver stiffness, attenuation, and the Velacurdetermined fat fraction (VDFF). In this study, the performance of Velacur was measured against biopsy results in a cohort of MASLD and MASH patients. Methods: This prospective study enrolled adult patients who were scheduled to undergo biopsy within 6 months of enrollment. The primary objective was to validate Velacur’s findings against that of histological findings. The secondary objective was to compare Velacur results with those of FibroScan. Results: A total of 78 participants were enrolled, and 70 were included in the analysis. Patients had a mean age of 53.3 ± 13.1 years, with a mean BMI of 35.0 ± 6.24 kg/m2. A total of 11, 19, 13, 25, and 2 were characterized as F0 to F4, respectively. The mean Velacur stiffness was 6.48 ± 1.4 kPa, and the mean VDFF was 14.4 ± 5.1%. In patients with significant fibrosis the Velacur AUC [95% CI] was 0.86 [0.76, 0.93] and 0.79 [0.66, 0.88] for patients with advanced fibrosis. For measurements of steatosis, 2, 24, 20, and 24 patients were found to have S0 to S3, respectively. To determine moderate steatosis (≥S2), the VDFF had an AUC of 0.846 [0.716, 0.920]. In the comparison population (n = 59), VDFF (0.85 [0.72, 0.94]) was significantly different than FibroScan CAP (0.50 [0.35, 0.66]) for the detection of moderate steatosis. Conclusions: This study validates the use of Velacur as a non-invasive tool for assessment of steatosis and fibrosis, hallmarks of MASLD and MASH, when compared to histological evidence provided via hepatic biopsy. Further, Velacur outperformed FibroScan in the assessment of steatosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.332

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.325
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueDiagnosticsSame topicLiver Disease Diagnosis and TreatmentFrench-language works237,207