MétaCan
Menu
Back to cohort
Record W4408575890 · doi:10.33279/jkcd.v15i01.757

IN-VIVO ANALYSIS OF OXIDATIVE STRESS IN AESTHETIC COATED ORTHODONTIC ARCH-WIRES & BRACKETS

2025· article· en· W4408575890 on OpenAlexaff
Iffat Batool Syed, Saira Khalid, Assad Abbas, Zahra Faisal, Husnain Abbas, Muhammad Azeem

Bibliographic record

VenueJournal of Khyber College of Dentistry · 2025
Typearticle
Languageen
FieldDentistry
TopicDental materials and restorations
Canadian institutionsCollège Montmorency
Fundersnot available
KeywordsArchIn vivoOxidative stressStress (linguistics)OrthodonticsMaterials scienceDentistryMedicineStructural engineeringEngineeringPhilosophyEndocrinologyBiology

Abstract

fetched live from OpenAlex

Objectives: To assess in vivo the oxidative damage that aesthetic coated arch-wires causes by measuring 8OHdG (8-hydroxydeoxyguanosine ) as an oxidative marker to detect the level of oxidative stress generation.Materials and Methods: About 80 patients of ages 15-30 years enrolled in the study having fi xed orthodontic treatment were divided into control (patients with NiTi wire) and experimental groups including patients with wires coated in PTFE, epoxy resin, and rhodium. Saliva samples were collected with an unstimulated saliva collection method at two intervals. The first sample was collected before the bonding process and insertion of the arch-wires and the second sample was collected four weeks after the insertion of arch-wires. The samples were kept in storage at -80°C, and the amounts of 8-OHdG were measured by ELISA analysis.Results: The salivary 8-OhdG level in all groups was measured at day 0 and the end of week 4. At day 0, It was 1.60±43 ng/ml in the NiTi group,1.60±0.52 ng/ml in the epoxy resin group, 1.70±0.12 ng/ml in the rhodium group and 1.63±0.40 ng/ml in PTFE group. After 4 weeks, it was 3.6810.47 ng/ml in the NiTi group, 3.50±0.77 ng/ml in the epoxy resin group, 3.06±0.70 ng/ml in the rhodium group and 2.75±0.72 ng/ml in PTFE group, p = 0.812) This demonstrated that while there was no noteworthy variation in the groups' mean 8-OHdG levels at day 0, there was at week 4. Post hoc Tukey test revealed that PTFE-coated arch-wires and Rhodium group had significantly lower 8-OHdG levels compared to NiTi and Epoxy resin-coated arch-wire. Salivary 8-OHdG levels increased significantly after 4 weeks of arch-wire use in all groups.Conclusion: This study suggests that PTFE-coated arch-wires are the most biocompatible among the coated arch-wires studied.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.315
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Khyber College of DentistrySame topicDental materials and restorationsFrench-language works237,207