Investigating Disturbance‐Induced Misoperation of Grid‐Following Inverter‐Based Resources

2025· article· en· W4408590565 on OpenAlexafffund
Negar Karimipour, Mohammadreza F. M. Arani, Amir Abiri Jahromi

Bibliographic record

VenueIET Generation Transmission & Distribution · 2025
Typearticle
Languageen
FieldEngineering
TopicHVDC Systems and Fault Protection
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsDisturbance (geology)InverterGridComputer scienceControl theory (sociology)Reliability engineeringControl engineeringEngineeringElectrical engineeringBiologyVoltageControl (management)MathematicsArtificial intelligence

Abstract

fetched live from OpenAlex

ABSTRACT The rapid integration of grid‐following inverter‐based resources (GFL‐IBRs) has increased the importance of their dynamic behaviour during disturbances. Simultaneously, there are increasing number of reports about the misoperation or inadvertent disconnection of GFL‐IBRs during disturbances. This paper attempts to shed light on one of the potential root causes of disturbance‐induced misoperations of GFL‐IBRs. A framework is presented to quantify voltage drop and voltage phase angle jump that appear at the terminals of GFL‐IBRs immediately after the inception of various events in the grid such as faults, and tripping of generators and transmission lines. We demonstrate voltage drop and voltage phase angle jump in the upstream grid due to various disturbances may transform into severe voltage drop and voltage phase angle jump at the terminals of GFL‐IBRs. The combination of voltage drop and voltage phase angle jump that appear at the terminals of GFL‐IBRs is identified as one of the root causes of their misoperation. Therefore, system‐wide studies are required to evaluate the dynamic performance of GFL‐IBRs rather than sole compliance with standards. The importance of system‐wide studies is demonstrated through IEEE 39‐bus test system. The impact of voltage drop and voltage phase angle jump in the upstream grid on the dynamic performance of GFL‐IBRs is demonstrated using electromagnetic transient studies.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.489
Threshold uncertainty score0.770

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.238
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueIET Generation Transmission & DistributionSame topicHVDC Systems and Fault ProtectionFrench-language works237,207