MétaCan
Menu
Back to cohort
Record W4408845824 · doi:10.1093/bjr/tqaf066

The importance of standardization and challenges of dosimetry in conventional preclinical radiation biology research

2025· review· en· W4408845824 on OpenAlexaff
Mark A. Hill, Ileana Silvestre Patallo, Adam Aitkenhead, Magdalena Bazalova‐Carter, Rebecca Carter, Simeon Nill, A. Nisbet, Mihaela Ghita, Yannick Poirier, Kevin M. Prise, Anna Subiel, Giuseppe Schettino

Bibliographic record

VenueBritish Journal of Radiology · 2025
Typereview
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Victoria
FundersNational Cancer InstituteCancer Research UKInstitute of Physics and Engineering in MedicineNational Cancer Research InstituteDepartment for Science, Innovation and TechnologyCancer Research Institute
KeywordsMedical physicsDosimetryStandardizationQuality assuranceTraceabilityMedical physicistConsistency (knowledge bases)Computer scienceRisk analysis (engineering)Protocol (science)MedicineNuclear medicine

Abstract

fetched live from OpenAlex

To fully exploit the prospects presented by the increasing focus on biological approaches for enhancing radiotherapy outcomes, improvements in repeatability and translatability of radiobiological and preclinical studies are required. This requires the development and adoption of appropriate dosimetric standards and reproducible approaches to increase confidence in the studies, enabling inter-laboratory validation and facilitating clinical translation. An Institute of Physics and Engineering in Medicine (IPEM) working party reviewed the current status and challenges associated with dosimetry of medium-energy X-rays and make recommendations with the aim to optimize the potential clinical significance of radiobiological preclinical investigations. The paper discusses the currently available resources with technical recommendations for performing dosimetry in medium-energy X-rays, along with the consequences of lack of standardization and implications of dose inhomogeneity. It is clear that there is still a gap in understanding the needs for standardization of dosimetric aspects of preclinical and radiobiological studies. It is recommended that these radiobiology studies should be conducted in partnership with medical/radiation physicists. This collaboration ensures the correct utilization of suitable dosimetry systems, thus guaranteeing accuracy and consistency of dose delivery. Appropriate calibration and traceability to national/international standards laboratory, along with regular quality assurance of radiation devices, are paramount to reproducibility. Additionally, it is critical that experimental details and associated dosimetry are sufficiently reported to ensure accurate replication that enables reanalysis including evaluation of dose distributions. Increasing awareness among the researchers and the funding bodies was identified as a crucial step to improve translatability and appropriate resources are budgeted to increase the value for money of research proposals. The proposed recommendations will serve as a vital resource for researchers, encouraging uniformity in experimental design and improving the translatability of preclinical research to clinical settings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.976
Threshold uncertainty score0.374

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.065
GPT teacher head0.446
Teacher spread0.381 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of RadiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207