MétaCan
Menu
Back to cohort
Record W4408911245 · doi:10.1161/circep.124.013619

One-Year Safety and Performance of a Dual-Chamber Leadless Pacemaker

2025· article· en· W4408911245 on OpenAlexaff
Reinoud E. Knops, James E. Ip, Rahul N. Doshi, Derek V. Exner, Pascal Defaye, Robert C. Canby, Maria Grazia Bongiorni, Morio Shoda, Gerhard Hindricks, Petr Neužil, Mayer Rashtian, Karel Breeman, Jordan R. Nevo, Leonard I. Ganz, Chris Hubbard, Anu Bulusu, Vivek Y. Reddy

Bibliographic record

VenueCirculation Arrhythmia and Electrophysiology · 2025
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsFoothills Medical Centre
Fundersnot available
KeywordsMedicineBradycardiaSick sinus syndromeAtrioventricular blockClinical endpointVentricleSinus bradycardiaCardiologyAtrioventricular nodeComplicationArtificial cardiac pacemakerLead (geology)Internal medicineAtrium (architecture)SurgeryHeart rateAtrial fibrillationRandomized controlled trialTachycardiaBlood pressure

Abstract

fetched live from OpenAlex

BACKGROUND: A dual-chamber leadless pacemaker can provide bradycardia therapy to most patients with pacemaker indications without the complications associated with a lead or pulse generator. We sought to confirm whether previously reported 3-month safety and performance outcomes were sustained through 12 months by determining whether 12-month complication-free and performance success rates exceeded their prespecified performance goals. METHODS: Patients were enrolled in the prospective, single-group Aveir DR i2i Study if they had a standard indication for dual-chamber pacing. Enrolled patients were implanted with an Aveir DR dual-chamber leadless pacemaker system, which comprised 2 communicating leadless pacemakers (1 in the right atrium and 1 in the right ventricle). The primary safety outcome evaluated whether freedom from serious device- or procedure-related events through 365 days exceeded the predetermined performance goal of 76.5%. The primary performance outcome determined whether the composite of atrial capture threshold (≤3.0 V at 0.4 ms) and sensing amplitude (P-wave ≥1.0 mV) at the 12-month visit exceeded the predetermined performance goal of 80.0%. RESULTS: Sites attempted implantation in 300 subjects, where 63.3% had sinus-node dysfunction and 33.3% had atrioventricular block as their primary pacing indication. The primary safety end point was achieved, with a Kaplan-Meier 12-month complication-free rate of 88.6% (95% CI, 84.5–91.8; P <0.001). The primary performance end point was achieved in 92.8% of patients (95% CI, 89.7–95.8; P <0.001). CONCLUSIONS: Both primary safety and performance end points were met after 1 year, demonstrating consistency with previously reported 3-month outcomes of a dual-chamber leadless pacemaker. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05252702.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.718
Threshold uncertainty score0.338

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.253
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueCirculation Arrhythmia and ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207