MétaCan
Menu
Back to cohort
Record W4408956721 · doi:10.1111/cpf.70005

Agreement of concomitant cardiac output measurement by thoracic bio‐impedance and inert gas rebreathing in healthy subjects

2025· article· en· W4408956721 on OpenAlex
Laura Filaire, Hélène Perrault, Claire Dauphin, Aurélie Chalard, Frédéric Costes, Ruddy Richard

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueClinical Physiology and Functional Imaging · 2025
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsMcGill UniversityUniversity of Ottawa
Fundersnot available
KeywordsMedicineConcomitantCardiologyInternal medicineCardiac outputImpedance cardiographyAnesthesiaBiomedical engineeringStroke volumeEjection fractionHemodynamicsHeart failure

Abstract

fetched live from OpenAlex

PURPOSE: Inasmuch as they are deemed valid, noninvasive measurement of cardiac output techniques present advantages of ease and safety for use in humans. Few studies have compared the use of thoracic bioimpedance and inert gas rebreathing techniques for cardiac output (CO) assessment at rest and exercise. This manuscript reports on differences between Physioflow® and Innocor® CO measurements at rest and during cycling in a population of healthy subjects. METHODS: Fifty healthy subjects (52 ± 16 years) underwent an incremental cycle exercise testing (IET) during which standardized Physioflow® and Innocor® CO assessments were achieved. Measurements were completed in a subgroup of twelve subjects during two constant-load 10-min cycling bouts at moderate and high intensities. RESULTS: Mean difference between Physioflow® and Innocor® was of 0.002 ± 0.98 l/min at rest and 0.38 ± 1.31 l/min during IET without statistical difference. Correlation coefficient values were higher for exercise (r = 0.83) than resting (r = 0.40) measurements. Good reproducibility of the two devices was observed on different graded exercises with intraindividual variability lower than 6%, except for rest Innocor® CO measurements (CV = 18%). CONCLUSION: Physioflow® and Innocor® can be easily used concomitantly for noninvasive measurement of CO. Despite finding a strong agreement between techniques for exercise CO, results should not be interpreted as being interchangeable as values are derived from different flow measurements: systemic blood flow for Physioflow® and pulmonary blood flow for Innocor®. However, the concomitant use of both techniques could be of value in clinical setting for noninvasive intrathoracic shunt quantification.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.170
Threshold uncertainty score0.378

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.366
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it