MétaCan
Menu
Back to cohort
Record W4409304844 · doi:10.1111/trf.18241

The feasibility of monitoring trauma patients with a wireless, wearable Doppler ultrasound

2025· article· en· W4409304844 on OpenAlexaff
Luís Teodoro da Luz, Sarah Atwi, Lowyl Notario, Rachael Irvine, Delaney Johnston, Jon‐Émile S. Kenny, Joseph K. Eibl, Dylan Pannell

Bibliographic record

VenueTransfusion · 2025
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsLaurentian UniversityHealth Sciences NorthHealth Sciences CentreSunnybrook Health Science Centre
Fundersnot available
KeywordsMedicineResuscitationTrauma centerProspective cohort studyBlood volumeEmergency medicineCardiologySurgeryRetrospective cohort study

Abstract

fetched live from OpenAlex

BACKGROUND: Early detection of reduced stroke volume (SV) or cardiac output (CO) may expedite resuscitative interventions during traumatic hemorrhage; corrected carotid artery flow time (ccFT) has been proposed as a surrogate for SV during blood volume loss. STUDY DESIGN AND METHODS: We conducted a prospective cohort study to assess the feasibility of using a wireless, wearable Doppler ultrasound capable of measuring ccFT in traumatically injured patients at a level 1 trauma center. A convenience sample of 33 patients was enrolled. We assessed device placement, data transfer and capture, and signal quality by assessing the ability to capture at least 15 consecutive cardiac cycles in the minute prior to blood pressure monitor cycling. A post hoc analysis examined ccFT variations between transfused and non-transfused patients. RESULTS: Device placement succeeded in 94% of patients (n = 31) and the data were captured and transferred from all 31. The consecutive cardiac cycles before blood pressure measurement exceeded 15 (p = .015) in 93% of patients (n = 28). We observed ccFT below 270 ms and longer time spent under this threshold during resuscitation in transfused patients. Patients with low ccFT experienced more severe injuries and longer hospital and ICU stays. DISCUSSION: This is the first study that demonstrates the feasibility of using a wearable Doppler ultrasound in trauma patients on admission to the trauma bay. Although findings suggest that ccFT could serve as an early marker of hemodynamic compromise, further large-scale, multicenter studies are needed to validate its predictive value and clinical utility in guiding trauma resuscitation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.058
Threshold uncertainty score0.245

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.280
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueTransfusionSame topicHemodynamic Monitoring and TherapyFrench-language works237,207