MétaCan
Menu
Back to cohort
Record W4409788171 · doi:10.1016/j.jacep.2025.04.008

PVI With CF-Sensing Large-Tip Focal PFA Catheter With 3D Mapping for Paroxysmal AF

2025· article· en· W4409788171 on OpenAlexaff
Mattias Duytschaever, Massimo Grimaldi, Tom De Potter, Atul Verma, Laurent Macle, Josef Kautzner, Dominik Linz, Ante Anić, Hugo Van Herendael, Gediminas Račkauskas, Petr Neužil, K. R. Julian Chun, Boris Schmidt, Sébastien Knecht, Alexandre Almorad, Benjamin Berte, Vivek Y. Reddy, Johan Vijgen

Bibliographic record

VenueJACC. Clinical electrophysiology · 2025
Typearticle
Languageen
FieldMedicine
TopicAtrial Fibrillation Management and Outcomes
Canadian institutionsMontreal Heart InstituteUniversité de MontréalMcGill University Health Centre
FundersBiosense WebsterEthiconJohnson and Johnson
KeywordsMedicineCatheterRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Omny-IRE (A Study For Treatment of Paroxysmal Atrial Fibrillation [PAF] With the OMNYPULSE Catheter and the TRUPULSE Generator) evaluated safety and effectiveness of a novel large-tip focal, multielectrode, contact force-sensing, pulsed field ablation catheter with electroanatomic mapping integration. OBJECTIVES: This study sought to assess 3-month safety and effectiveness of the platform for treating symptomatic paroxysmal atrial fibrillation. METHODS: Pulmonary vein isolation (PVI) was performed using the OMNYPULSE Platform. Primary effectiveness was adenosine/isoproterenol-proof entrance block. Primary safety was occurrence of primary adverse events. Prespecified patient subsets underwent systematic brain imaging, esophageal endoscopy, cardiac computed tomography/magnetic resonance angiogram, and mandatory 3-month remapping for PVI durability assessment. RESULTS: Of 188 patients enrolled, 136 were included in the per-protocol analysis. Primary effectiveness was 100% (136 of 136). Median (Q1-Q3) procedure, left atrial dwell, total ablation, and total fluoroscopy times were 105.5 (91.0-124.0), 70.0 (56.0-81.5), 46.9 (37.1-58.8), and 5.0 (3.1-9.8) minutes, respectively. The primary adverse event rate was 3.0% (4 of 135 patients with 3-month follow-up; 3 major vascular access complications, 1 pericarditis). Brain imaging (n = 30) revealed 1 patient (3.3%) with an asymptomatic silent cerebral event at discharge, which resolved at 1 month without neurological change. No esophageal injury was observed. Computed tomography/magnetic resonance angiogram imaging (n = 24) showed no incidences of pulmonary vein narrowing >70%. During remapping, PVI was durable in 84.5% (98 of 116) of veins and 62.1% (18 of 29) of patients. With an optimized workflow, PVI durability improved to 89.3% (75 of 84) and 71.4% (15 of 21) of veins and patients, respectively. CONCLUSIONS: The force-sensing, large-focal pulsed field ablation catheter with 3-dimensional electroanatomic mapping integration showed 100% acute success with a promising safety profile for treating paroxysmal atrial fibrillation. Prespecified remapping showed good PVI durability. (A Study For Treatment of Paroxysmal Atrial Fibrillation [PAF] With the OMNYPULSE Catheter and the TRUPULSE Generator; NCT05971693).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.303
Threshold uncertainty score0.709

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.387
Teacher spread0.325 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJACC. Clinical electrophysiologySame topicAtrial Fibrillation Management and OutcomesFrench-language works237,207