Ex Vivo Microsuturing of the Human Anterior Lens Capsule Using 10-0 Sutures: A Technical Feasibility Report

2025· article· en· W4409832146 on OpenAlexaboutno aff
Joobin Khadamy, Pontus Lithén

Bibliographic record

VenueCureus · 2025
Typearticle
Languageen
FieldMedicine
TopicIntraocular Surgery and Lenses
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineEx vivoCapsuleLens (geology)Lens capsuleOphthalmologyIn vivoAnatomySurgeryBiomedical engineeringOpticsIntraocular lens

Abstract

fetched live from OpenAlex

The human lens capsule is a robust, transparent basement membrane commonly discarded during cataract surgery. Although its use as a biological graft has gained interest in ocular surgery, practical methods for securing the capsule, such as suturing, have not been evaluated. This technical report presents the first in vitro assessment of anterior lens capsule sutureability using fine 10-0 sutures. Anterior capsule specimens were obtained from two patients with pseudoexfoliation syndrome undergoing routine cataract surgery. After being stored for four hours in balanced salt solution (BSS), the specimens, one stained with trypan blue and the other unstained, were spread on a plastic surface (a cellophane sheet: as a non-biologic backing substrate) and sutured using 10-0 nylon (Ethilon™, Ethicon, Raritan, NJ, USA) and 10-0 polyglactin 910 (Vicryl™, Ethicon, Raritan, NJ, USA) under an operating microscope. Both suture types could be successfully passed through the capsule without immediate tearing. The stained capsule enhanced visibility but appeared slightly more fragile, while the unstained capsule demonstrated greater elasticity. Attempts to reapproximate full-thickness capsule tears using sutures were unsuccessful. Viscoelastic agents, including MiniVisc® Plus (Bausch + Lomb, Vaughan, Canada) and DisCoVisc® (Alcon Laboratories, Fort Worth, TX, USA), did not aid in capsule stabilization and reduced visibility during manipulation. No specialized instruments beyond standard ophthalmic tools were used. These findings demonstrate that human anterior lens capsules can tolerate fine suturing in vitro and suggest their potential as suturable biological grafts in applications such as corneal patching, pterygium surgery, or ocular surface reconstruction. However, limitations in tear repair and in vivo behavior require further investigation to establish clinical utility.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.142
Threshold uncertainty score0.359

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.343
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueCureusSame topicIntraocular Surgery and LensesFrench-language works237,207