Accuracy of Anterior Immediate Versus Delayed Implant Placement With an Autonomous Robotic System: A Retrospective Study

2025· article· en· W4409962931 on OpenAlexvenueno aff
Danhong Zhou, Yunxuan Chen, He Jin, Danji Zhu, Zhiwei Jiang, Guoli Yang

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2025
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersNational Natural Science Foundation of China
KeywordsMedicineImplantMann–Whitney U testCoronal planeRetrospective cohort studyVisual analogue scaleExact testPatient satisfactionCone beam computed tomographyDentistrySurgeryOrthodonticsComputed tomographyRadiology

Abstract

fetched live from OpenAlex

OBJECTIVE: This study aimed to compare the accuracy of an autonomous robotic system for anterior immediate and delayed implant placement. METHODS: This retrospective study included patients who underwent anterior dental implant surgery from September 2022 to March 2025 using an autonomous robotic system. Osteotomies performed with the autonomous robotic system in this study were modified by using precision and side-cutting drills, along with repeated lifting of drills to minimize deviations. Linear and angular deviations in two- and three-dimensional space were assessed by matching preoperative planning with postoperative cone beam computed tomography. Postoperative pain and surgical satisfaction were recorded using a 100-mm visual analog scale. The Shapiro-Wilk test, Student's t-test, Mann-Whitney U-test, Pearson's Chi-Square test, and Fisher's exact test were used, and p < 0.05 was considered statistically significant. RESULTS: This retrospective study included 53 patients (65 implants) who underwent anterior dental implant surgery with the autonomous robotic system (immediate implant placement group: 19 patients, 21 implants; delayed implant placement group: 34 patients, 44 implants). Comparison of deviations in immediate and delayed implantation using the autonomous robotic system showed a mean (± SD) coronal deviation of 0.57 ± 0.19 mm versus 0.49 ± 0.20 mm (p = 0.129), a mean apical deviation of 0.57 ± 0.19 mm versus 0.52 ± 0.21 mm (p = 0.373), and a mean angular deviation of 0.53° ± 0.18° versus 0.61° ± 0.28° (p = 0.742). Postoperative pain and surgical satisfaction were not significantly different between the two groups (p > 0.05). CONCLUSIONS: The autonomous robotic system demonstrated high and comparable accuracy in both anterior immediate and delayed implantation, with overall patient satisfaction. This could reduce the technical sensitivity of anterior immediate implant placement, enhance precision, and broaden the clinical applications of the autonomous robotic system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.082
GPT teacher head0.459
Teacher spread0.376 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→