MétaCan
Menu
Back to cohort
Record W4410001322 · doi:10.2196/66013

Improved Speech Recognition in Adults With Conductive or Mixed Hearing Loss Using a Direct-to-Consumer Bone-Conduction Device: A Multiple Methods Intervention Study

2025· article· en· W4410001322 on OpenAlexvenueno aff
Thomas Hampton, M. Fletcher, Alan Sanderson, Manuel Loureiro, Kevin Mortimer, Mahmood F. Bhutta

Bibliographic record

VenueJMIR Rehabilitation and Assistive Technologies · 2025
Typearticle
Languageen
FieldMedicine
TopicEar Surgery and Otitis Media
Canadian institutionsnot available
FundersWellcome Trust
KeywordsBone conductionAudiologyHeadsetHearing lossConductive hearing lossMedicineSpeech perceptionOtosclerosisPerceptionPsychologyTelecommunicationsComputer science

Abstract

fetched live from OpenAlex

Background: Hearing loss affects 20% of the global population, including 250 million experiencing chronic suppurative otitis media, which can present challenges for conventional hearing aids due to ear discharge. Although assistive technology for hearing is available in high-income settings, provision is poor in low-income settings due to high costs and low availability of audiology services, reaching approximately 3% of those who could benefit from it. Objective: This study aimed to evaluate the performance of a low-cost self-fitted direct-to-consumer bone-conduction headset for individuals with conductive or mixed hearing loss. Methods: We conducted a multiple methods study to test the efficacy and acceptability of this device using a purposive sample. Participants with a range of conductive and mixed hearing loss underwent speech-in-quiet speech audiometry with and without the device and took part in feedback interviews exploring their subjective impressions of the device. Results: In 33 participants, the device improved speech recognition in those with bone conduction thresholds <50 dB by a median of 11%, with larger air-bone gap associated with larger improvement. Participants rated the device positively on weight, style, and ease of use. Conclusions: This multiple methods study assessed the acceptability and efficacy of a low cost self-fitted bone-conduction device in adults. We found the device provides hearing benefit for those with conductive or mixed hearing loss (with bone conduction thresholds <50dB HL). Those with significant conductive hearing loss were measured to have their speech perception significantly improved. Participants had a mixed response to device aesthetics. Further studies should seek to establish if this type of device has effectiveness in real-world trials and which individuals are most likely to benefit. This low cost device could provide hearing benefits to millions of people without access to other devices. Product designers and clinical researchers should explore device optimization. Given the economic impacts of hearing loss across the globe, this style of self-fitted device could represent a paradigm shift in future assistive technology for hearing loss, in both high and low resource settings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: Non-randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.380
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Rehabilitation and Assistive TechnologiesSame topicEar Surgery and Otitis MediaFrench-language works237,207