MétaCan
Menu
Back to cohort
Record W4410037493 · doi:10.1186/s13054-025-05416-5

Erroneous calibration of esophageal pressure in case of airway closure

2025· article· en· W4410037493 on OpenAlexafffund
Mattia Docci, François Beloncle, Arnaud Lesimple, Thomas Piraino, Davide Raimondi Cominesi, Andrea Restivo, Mayson Laércio de Araújo Sousa, Emanuele Rezoagli, Alain Mercat, Jean-Christophe M. Richard

Bibliographic record

VenueCritical Care · 2025
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsUniversity of ManitobaMuscular Dystrophy CanadaMcMaster UniversityUniversity of Toronto
FundersCerebraUniversité du Québec à Trois-Rivières
KeywordsMedicineAirwayPositive end-expiratory pressureAnesthesiaMechanical ventilationContinuous positive airway pressureExpirationVentilation (architecture)Internal medicineRespiratory systemObstructive sleep apnea

Abstract

fetched live from OpenAlex

Airway closure results in a lack of communication between proximal and distal airways unless the airway pressure (Paw) overcomes the airway opening pressure (AOP). This has been described in patients undergoing mechanical ventilation with acute respiratory distress syndrome, obesity, hydrostatic pulmonary edema and during cardiopulmonary resuscitation. In these categories of patients, esophageal pressure (Pes) can guide the personalization of mechanical ventilation and calibration of the esophageal balloon is necessary to obtain reliable Pes measurements. The impact of airway closure has never been envisaged. This study investigated the impact of airway closure on the calibration of the esophageal balloon by the ∆Paw/∆Pes following a positive pressure occlusion test during passive mechanical ventilation. The calibration test was performed in twelve human cadavers with airway closure at end-expiration at different levels of positive end-expiratory pressure (PEEP) and at end-inspiration. The ∆Paw/∆Pes measured at end-expiration and at end-inspiration were significantly different when total PEEP was lower than AOP (estimated means 0.42 [0.40; 0.44] vs. 0.95 [0.92; 0.97], P < 0.001), while this difference was not observed when total PEEP was higher than AOP (estimated means 0.99 [0.92; 1.05] vs. 0.99 [0.92; 1.06], P = 0.854). These results were corroborated by observations during esophageal balloon calibration in two patients requiring Pes monitoring for clinical management. In case of airway closure, compression of the chest is not fully transmitted to the airways. This can lead to a conspicuous underestimation of the ∆Paw/∆Pes and poor reliability of this monitoring technique when the test takes place below AOP. Our results favor a positive pressure occlusion test performed during an end-inspiratory occlusion as the new standard of operative procedures for positioning and calibrating the esophageal balloon.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.328
Teacher spread0.313 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueCritical CareSame topicRespiratory Support and MechanismsFrench-language works237,207