Validation of Gait Kinematics With Ramp and Stair Ascent and Descent Revealed by Markerless Motion Capture in Simulated Living Space: Test-Retest Reliability Study
Bibliographic record
Abstract
Background: In recent years, there has been an increasing demand for markerless motion capture systems, which are being widely used in biomechanical and clinical research. Furthermore, by using a markerless motion capture system in a laboratory environment that mimics living spaces, the data acquired on various activities of daily living, such as level walking, ramp walking, and stair ascent and descent, should more closely resemble that of real-life activities. However, the absolute reliability of gait parameters in this context is still unclear. Objective: The aim of this study was to evaluate the reliability of a markerless motion capture system in assessing the ascent and descent of ramps and stairs during walking in a simulated living space. Methods: A total of 21 healthy participants performed level walking, ramp and stair ascent and descent on two separate days, with at least a 24-hour interval between sessions. Joint angles were measured using 27 synchronized cameras with a markerless motion capture application, Theia3D (Theia Markerless Inc), and analyzed in Visual3d for all planes of motion at the hip-, knee-, and ankle-joints. The absolute reliability of day-to-day reproducibility was assessed using full-curve analysis (root mean square difference [RMSD]) and discrete point analysis of gait events using the standard error of measurement (SEM). SEM was calculated only for level walking and ramp ascent and descent, where gait events were correctly detected. Results: The SEM values for level walking and ramp ascent and descent were all below the 5-degree threshold. However, while RMSD values were generally below 5°, this threshold was exceeded for knee-joint flexion-extension angles during ramp ascent and stair ascent (5.07° and 5.64°, respectively). Conclusions: The markerless motion capture system in the living laboratory setting demonstrated a high degree of accuracy for various environments and gait types. The low SEM values obtained indicate good reliability for joint angle measurements across different days. The slightly higher RMSD values for knee-joint angles during ramp and stair ascent may reflect the system's ability to capture the adaptations in joint kinematics in response to changes in gait conditions. These measurements in a living laboratory environment validated the absolute reliability of various gait parameters not only in level walking but also in ramp and stair ascent and descent. The findings suggest potential clinical applications and research opportunities, including the development of assistive devices and robots, using markerless motion capture in more natural living situations, rather than in controlled environments.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.005 | 0.010 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".