MétaCan
Menu
← Back to cohort
Record W4410608397 · doi:10.1111/hdi.13261

Catheter‐Related Infection in Uncuffed, Non‐Tunneled Dual‐Lumen Catheters: Incidence and Risk Factors by Internal Jugular Versus Femoral Site in a Retrospective Cohort

2025· article· en· W4410608397 on OpenAlexvenueno aff
Tanwaporn Phatpituk, Suthiya Anumas, Aphichat Chatkrailert

Bibliographic record

VenueHemodialysis International · 2025
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsnot available
FundersThammasat University
KeywordsMedicineCatheterSurgeryIncidence (geometry)Retrospective cohort studyLumen (anatomy)Hemodialysis

Abstract

fetched live from OpenAlex

BACKGROUND: Uncuffed, non-tunneled dual-lumen catheters are often required for kidney replacement therapy (KRT), but catheter-related bloodstream infections (CRBSIs) remain a serious complication. Whether the jugular site poses a lower CRBSI risk than the femoral site is unclear. METHODS: This retrospective cohort study analyzed patients with uncuffed, non-tunneled dual-lumen catheters. CRBSI incidence, catheter dwelling time, and mortality rates were compared between jugular and femoral sites. Regression analyses identified CRBSI risk factors. RESULTS: A total of 572 patients were included in the study. The incidence proportion of CRBSI was 3.5% in both the femoral and jugular groups (10 of 286 patients in each group; p = 1.0). The incidence rates of CRBSI were 1.7 and 0.9 per 1000 patient-days for the femoral and jugular sites, respectively (p = 0.154). The median catheter dwelling time was significantly longer for jugular catheters (25 days) compared to femoral catheters (12 days; p < 0.001). The 30-day incidence proportion of death at the jugular site was significantly lower than at the femoral site (0.105 vs. 0.608, p < 0.001). Pre-existing cerebrovascular disease and congestive heart failure were identified as significant risk factors for CRBSI. CONCLUSION: For uncuffed, non-tunneled dual-lumen catheters used for dialysis vascular access, the jugular insertion site does not demonstrate a reduced risk of CRBSI compared to the femoral site. However, jugular catheter placement is associated with a longer dwelling time and a lower mortality rate.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.314
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis International→Same topicCentral Venous Catheters and Hemodialysis→French-language works237,207→