MétaCan
Menu
← Back to cohort
Record W4410724343 · doi:10.1111/hdi.13254

Use of the B. Braun Hemodialysis Machine to Provide Home Hemodialysis

2025· article· en· W4410724343 on OpenAlexvenueno aff
Rachid Daoui, Paul J. Feustel, Christina Manning, Loay Salman

Bibliographic record

VenueHemodialysis International · 2025
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsHemodialysisMedicineGroup BHome hemodialysisDialysisPeritoneal dialysisRetrospective cohort studyInternal medicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Home hemodialysis (home HD) continues to be an underutilized dialysis modality despite its potential advantages when compared to peritoneal dialysis (PD) and in-center hemodialysis (HD). METHODS: We conducted a retrospective study to evaluate the feasibility of using the B. Braun Dialog+ HD machine to provide home HD with the necessary requirements and modifications at home to be able to provide such treatments. In this retrospective study, we compared data obtained from patients who received home HD using the B. Braun Dialog+ HD machine since we started utilizing it for home HD (n = 27 patients) to data obtained from eligible patients who received home HD using the NxStage System One machine around the same period (n = 36 patients). RESULTS: Our results showed that the B. Braun group had a better single treatment single-pool Kt/V (spKt/V) (1.48 ± 0.27 for B. Braun vs. 1.14 ± 0.32 for NxStage, p < 0.001), better standard weekly Kt/V (4.44 ± 0.82 for B. Braun vs. 2.65 ± 0.57 for NxStage, p < 0.001), and better urea reduction rate (URR) (71.4 ± 6.2 for B. Braun vs. 59.2 ± 9.1 for NxStage, p < 0.001). The duration for the HD treatments among the B. Braun group patients was significantly shorter than that of the NxStage group patients (3.48 ± 0.32 vs. 4.58 ± 1.52, p < 0.001) while the ultrafiltration rate for the B. Braun group patients was significantly larger than that of the NxStage group patients (1.83 ± 0.64 vs. 1.18 ± 0.66, p < 0.001). The average laboratory data for both groups showed that there was only a significant difference between the two groups in bicarbonate level, with B. Braun having a lower level (23.5 ± 2.0 for B. Braun vs. 24.9 ± 2.8 for NxStage, p = 0.021). There were no significant differences between the two groups in the average albumin, BUN, calcium, creatinine, hemoglobin, phosphorus, platelets, potassium, WBC, or PTH. CONCLUSION: B. Braun HD machine is another HD device that can be considered to provide home HD. Our study has shown that B. Braun machine had higher spKt/V in addition to standard weekly Kt/V and URR when compared to the NxStage machine. Larger, well-designed, and well-powered studies are needed to confirm these results.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.272
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis International→Same topicDialysis and Renal Disease Management→French-language works237,207→