Case Report of an Unexpected Cause of Noisy Breathing: Breast Pump Membrane as an Esophageal Foreign Body in an Infant
Bibliographic record
Abstract
Background:Due to their nonspecific symptoms, foreign bodies in the aerodigestive tract (FBA) are often misdiagnosed as respiratory conditions, especially when unwitnessed, posing significant risks for morbidity and mortality in the pediatric population. Case Presentation:We report a case of an otherwise healthy 4-month-old, predominantly breastfed infant with episodic “honking” breathing, choking with feeds, and a 2-month history of recurrent croup episodes requiring emergency services and an hospital admission. After referral to pediatric otolaryngology/respirology, a flexible laryngoscopy revealed a diagnosis of mild laryngomalacia, inconsistent with the severity of symptoms. A formal airway evaluation was performed, including supraglottoplasty. Results:Unexpectedly, extraluminal pulsatile tracheal compression was found, with correlating computed tomography findings of an innominate artery variation and a paraesophageal abnormality. This abnormality appeared as a fluid-filled density between the esophagus and trachea on magnetic resonance imaging, without patency to the esophagus on Upper GI series. Differential diagnoses included vascular malformation, esophageal diverticulum, and bronchogenic/foregut duplication cyst. Although evaluation with echoendoscopy was considered, collaboration with general/thoracic surgery for a flexible esophagoscopy revealed a 2-cm breast pump membrane embedded in a pseudo-diverticulum with a sealed esophageal perforation, which concluded with successful object removal via forceps. The patient’s respiratory symptoms have resolved; however, persistence of the pseudo-diverticulum on follow-up imaging and endoscopy warrants ongoing surveillance. Conclusion:This case demonstrates the challenging diagnosis of a breast pump membrane as an unexpected esophageal FBA, compounded by nonspecific respiratory symptoms and the membrane’s near-radiolucency on standard imaging. The exhibited multidisciplinary, collaborative approach was fundamental for the complication-free removal of the membrane.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.002 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.002 | 0.000 |
| Bibliometrics | 0.001 | 0.002 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".