MétaCan
Menu
Back to cohort
Record W4411350734 · doi:10.1016/j.nima.2025.170713

Defect investigation in irradiated ATLAS18 ITk Strip Sensors using transient spectroscopy techniques

2025· article· en· W4411350734 on OpenAlexafffund
C. Klein, V. Cindro, J. R. Dandoy, V. Fadeyev, P. Federičová, C. E. Jessiman, J.S. Keller, T. Koffas, J. Kroll, J. Kvasnička, I. Mandić, M. Mikeštíková, E. J. Staats, M. Ullán, Y. Unno, Y. Zhao

Bibliographic record

VenueNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicParticle Detector Development and Performance
Canadian institutionsCarleton University
FundersNatural Sciences and Engineering Research Council of CanadaJavna Agencija za Raziskovalno Dejavnost RSAgencia Estatal de InvestigaciónMinisterstvo Školství, Mládeže a TělovýchovyForskningsrådet om Hälsa, Arbetsliv och VälfärdCERNCanada Foundation for InnovationU.S. Department of Energy
KeywordsTransient (computer programming)IrradiationSpectroscopyMaterials scienceComputer sciencePhysicsNuclear physicsAstronomyProgramming language

Abstract

fetched live from OpenAlex

With the upgrade of the LHC to the High-Luminosity LHC (HL-LHC), the Inner Detector will be replaced with the new all-silicon ATLAS Inner Tracker (ITk). Comprising an active area of 165 m 2 , the outer detector layers will host strip modules, built with single-sided micro-strip sensors. The ATLAS18 main sensors were tested at different institutes in the collaboration for mechanical and electrical compliance with technical specifications, while technological parameters were verified on test structures from the same wafers before and after irradiation. Diodes fabricated as test structures were studied using variants of Deep-Level Transient Spectroscopy (DLTS). Irradiated diode samples were measured with Current-DLTS, using both electrical and photo-induced injection. Utilising DLTS spectra with varying test parameters, trap energy levels and cross-sections associated with defects were obtained. This was done to improve the precision of sensor simulations as well as to compile a more complete model of radiation damage in ITk Strip Sensors. Moreover, previously observed features such as an increasing trend in the full depletion voltage after irradiation and little beneficial annealing in charge collection after high fluence irradiation of high energy protons were also investigated. Results obtained for samples with radiation damage from different sources at various fluences were compared.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.045
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.389
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueNuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated EquipmentSame topicParticle Detector Development and PerformanceFrench-language works237,207