MétaCan
Menu
← Back to cohort
Record W4411729910 · doi:10.1016/j.jacc.2025.06.017

1-Year Results From a Multicenter Trial of a Polymer Surgical Mitral Valve

2025· article· en· W4411729910 on OpenAlexaff
Isaac George, Dasari Prasada Rao, Anil Jain, Guido Ascione, Mohit Sharma, ZS Meharwal, Binay Krishna Sarkar, Nitin I. Kochar, Naman Shastri, James Runt, Brian Whisenant, B D Wilson, Andy C. Kiser, Martin B. Leon, Kaushal Pandey

Bibliographic record

VenueJournal of the American College of Cardiology · 2025
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSt. Clair College
Fundersnot available
KeywordsMedicineCenter (category theory)Mitral valveCardiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Polymer leaflet material may extend the durability of surgical mitral valve replacement (SMVR) to provide stable long-term hemodynamics. The India Mitral Surgical Trial sought to evaluate the safety and performance of a novel polymer leaflet material as part of a surgical mitral valve (MV) prosthesis. OBJECTIVES: In this study, the authors sought to report 1-year outcomes in patients undergoing SMVR for MV disease using the Tria Mitral Valve (Foldax). METHODS: Adult patients requiring MV replacement were enrolled in a prospective single-arm multicenter trial at 8 clinical sites in India from April to November 2023. An independent physician screening committee reviewed each patient for study eligibility before enrollment. Safety events were adjudicated per standard Valve Academic Research Consortium 3 criteria guidelines, and valve performance was assessed by means of echocardiographic and computed tomographic imaging at 30 days and 1 year. Patients were maintained on a vitamin K antagonist (target international normalized ratio: 2.5). RESULTS: and 4.6 ± 1.7 mm Hg, respectively. There were 2 thrombotic events and 3 ischemic strokes, all in patients with subtherapeutic international normalized ratio. CONCLUSIONS: The polymer surgical MV demonstrated an acceptable safety profile and maintained stable hemodynamic performance through 1 year in patients undergoing MV replacement. Further study of this promising polymer leaflet technology is ongoing. (Clinical Investigation for the Foldax Tria Mitral Valve-India; NCT06191718).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.026

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.005
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0040.004
Bibliometrics0.0000.000
Science and technology studies0.0010.002
Scholarly communication0.0020.003
Open science0.0010.001
Research integrity0.0030.005
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.322
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2025
Admission routes1
Has abstractno

Explore more

Same venueJournal of the American College of Cardiology→Same topicCardiac Valve Diseases and Treatments→French-language works237,207→