MétaCan
Menu
Back to cohort
Record W4412008032 · doi:10.3390/s25134145

Comb-Tipped Coupled Cantilever Sensor for Enhanced Real-Time Detection of E. coli Bacteria

2025· article· en· W4412008032 on OpenAlexafffund
Syed Ali Raza Bukhari, Elham Alaei, Zongchao Jia, Yongjun Lai

Bibliographic record

VenueSensors · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicMechanical and Optical Resonators
Canadian institutionsQueen's University
FundersNatural Sciences and Engineering Research Council of CanadaQueen's UniversityEli Lilly and Company
KeywordsCantileverBacteriaMaterials scienceComputer scienceNanotechnologyBiologyComposite material

Abstract

fetched live from OpenAlex

The detection of particulate matter, particularly pathogenic bacteria, is essential in environmental monitoring, food safety, and clinical diagnostics. Among the various sensing techniques used, cantilever-based sensors offer a promising platform for label-free, real-time detection due to their high sensitivity. Here, we present a coupled cantilever sensor incorporating interdigitated comb-shaped structures to enhance dielectrophoretic (DEP) capture of Escherichia coli in liquid samples. During operation, one cantilever is externally actuated and the other oscillates passively through fluid-mediated coupling. The sensor was experimentally evaluated across a broad concentration range from 10 to 105 cells/mL and the resonant frequency shifts were recorded for both beams. The results showed a strong linear frequency shift across all tested concentrations, without saturation. This demonstrates the sensor’s ability to detect both trace and high bacterial loads without needing recalibration. High frequency shifts of 4863 Hz were recorded for 105 cells/mL and 225 Hz for the lowest concentration of 10 cells/mL, giving a limit of detection of 10 cells/mL. The sensor also showed a higher signal to noise ratio of 265.7 compared to previously reported designs. These findings showed that the enhanced sensor design enables sensitive, linear, and reliable bioparticle detection across a wide range, making it suitable for diverse applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.020
Threshold uncertainty score0.506

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.245
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueSensorsSame topicMechanical and Optical ResonatorsFrench-language works237,207