MétaCan
Menu
← Back to cohort
Record W4412110583 · doi:10.1111/cid.70078

Comparison of Different Frameworks and Implant Angulations in All‐On‐Four and Six Concepts: A Finite Element Analysis

2025· article· en· W4412110583 on OpenAlexvenueno aff
Cumhur Korkmaz

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2025
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsFinite element methodImplantDentistryOrthodonticsDental implantComputer scienceMedicineStructural engineeringEngineeringSurgery

Abstract

fetched live from OpenAlex

OBJECTIVES: The study aimed to compare the biomechanical behaviors in the all-on-four and all-on-six concept prostheses of different framework materials (cobalt-chromium Co-Cr, titanium Ti, and polyetheretherketone PEEK) and posterior implant angulation in the completely edentulous maxilla. MATERIAL AND METHODS: According to the all-on-four and all-on-six concepts, four different three-dimensional (3D) models were created for the completely edentulous maxilla. The posterior implants were positioned in the premolar region, 30° and 45° angled distally. The frameworks were designed and simulated using the material properties of Co-Cr, Ti, and PEEK. A load of 200 N in the palatobuccal direction was applied to the occlusal surface of the posterior implants bilaterally. The von Mises, maximum, and minimum principal stresses were obtained. RESULTS: In both concepts, the stress values of the PEEK framework were significantly higher than the stress values of Co-Cr and Ti frameworks in terms of implant, cortical bone, and abutment. The highest von Mises value between frameworks was determined in the Co-Cr framework in the all-on-six concept. Implants with a 45° angle in the posterior showed higher stress values than implants with a 30° angle. CONCLUSION: As the number of implants increased, the stress on the implant and cortical bone decreased, while it increased on the abutment and prosthetic framework. The increase in the tilt angle of the posterior implants was directly proportional to the rise in stress concentration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.002
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.163
GPT teacher head0.543
Teacher spread0.380 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→