MétaCan
Menu
Back to cohort
Record W4413987883 · doi:10.1111/opo.70009

Radiometric and safety assessment of a ‘low‐level red‐light’ myopia control device

2025· article· en· W4413987883 on OpenAlex
Josh Richards, Jennifer J. Hunter, Francisco Javier Gantes-Nuñez, Arthur Bradley, Pete Kollbaum

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueOphthalmic and Physiological Optics · 2025
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsUniversity of Waterloo
FundersCooperVision
KeywordsCollimated lightOpticsMaterials scienceDiodeLaser safetyLaserPhysicsOptoelectronics

Abstract

fetched live from OpenAlex

Abstract Purpose Recent literature has demonstrated that ‘low‐level red‐light therapy’ may be effective at slowing axial elongation in children, but reports have questioned the safety of some red‐light devices. The current work explored the beam characteristics and hazard potential for a myopia control red‐light device. Methods The optical design and exiting beam characteristics of a sample red‐light myopia control device (SECONEE sky‐n1201a) were quantified by measuring beam divergence and total flux passing through artificial pupils of 1–9 mm diameter placed at the corneal plane. Retinal exposure levels were compared to American National Standards Institute (ANSI) limits for ophthalmic instruments (Z80.36‐2021). Results Two 655 nm laser diodes created exiting red‐light beams (~9 mm in diameter) that were approximately collimated by an internal pair of +10.00 D eye‐piece lenses resulting in exit vergences ranging from −3.25 to −7.75 D as interpupillary distance settings were adjusted from 52 to 70 mm. Radiant power (mW) passing through the artificial pupils increased from 0.005 to 0.65 mW as pupil diameters increased from 1 to 9 mm. Using ANSI Z80.36‐2021, time‐averaged retinal radiant exposures (J/cm 2 ) exceeded the thermal and photochemical limits for pupil diameters >1 mm and >5 mm, respectively. The time to reach potential photochemical radiation hazard ( t max ) was less than 100 s for pupil diameters >5 mm. Conclusions The optical design and resulting beam characteristics of this sample red‐light myopia control device generate retinal exposure levels that vary with pupil diameter, accommodation and eye movements. Conservative estimates reveal retinal radiant exposures that can exceed ANSI safety limits. The ‘low‐level’ moniker is inappropriate for a device that either exceeds or is just below the ANSI threshold for potential retinal hazard.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.117
Threshold uncertainty score0.535

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.382
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it