MétaCan
Menu
Back to cohort
Record W4414077547 · doi:10.1016/j.jocmr.2025.101955

Full free-breathing cardiovascular magnetic resonance imaging: enhancing efficiency and image quality in clinical practice

2025· article· en· W4414077547 on OpenAlexaff
Kai Yang, Chen Cui, Fei Teng, Gang Yin, Jing An, Xinling Yang, Jinghui Li, Xiaoming Bi, Jianing Pang, Kelvin Chow, Shihua Zhao, Minjie Lu

Bibliographic record

VenueJournal of Cardiovascular Magnetic Resonance · 2025
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsSiemens (Canada)
FundersChinese Academy of Medical Sciences Initiative for Innovative MedicineFundamental Research Funds for the Central UniversitiesNational Key Research and Development Program of China
KeywordsClinical PracticeAngiologyImage qualityMagnetic resonance imagingQuality (philosophy)Cardiac magnetic resonanceImage enhancement

Abstract

fetched live from OpenAlex

BACKGROUND: Conventional cardiovascular magnetic resonance (CMR) examinations require patients to repeatedly hold their breath, which can reduce examination efficiency and pose challenges for patients unable to do so. This study aimed to demonstrate the feasibility and effectiveness of a full free-breathing CMR protocol in clinical practice. METHODS: Patients prospectively enrolled in this study underwent a full free-breathing CMR exam on a 3T scanner between June 1 and June 30, 2024. Acquisition time and image quality were assessed. Cine and flow imaging were compared with those acquired with the conventional breath-holding CMR protocol. Other sequences, including T1/T2 mapping and late gadolinium enhancement (LGE), were evaluated quantitatively and qualitatively, respectively. Group comparisons were performed using the Wilcoxon signed-rank test or paired t-test. Consistency was assessed using Kappa statistics, Bland-Altman statistics, intraclass correlation coefficient (ICC), and linear regression. RESULTS: A total of 211 patients were evaluated (median age: 53 years [IQR: 38-63]; range: 10-82 years; 145 men). The mean acquisition time for full free-breathing CMR was 22.6±3.7 min. The median image quality scores for cine and LGE images acquired with free-breathing CMR were 4 (IQR: 4-4) and 5 (IQR: 4-5), respectively. Compared with conventional breath-holding CMR, the end-diastolic volume (EDV), end-systolic volume (ESV), EDV index, and ESV index measured by free-breathing CMR were slightly higher (all P<0.05), whereas the left ventricular ejection fraction and left ventricular mass were slightly lower (both P<0.05). Nonetheless, the two methods demonstrated good agreement and correlation (r values: 0.85-0.99). Native T1 and T2 values in healthy subjects from free-breathing CMR were 1214.9±16.7ms and 38.4±3.2ms, respectively. Among the 211 patients, 147 were LGE positive. Except for five patients with image quality scores below 3, all others had scores of 3 or higher. CONCLUSION: Full free-breathing CMR examinations are feasible and effective in clinical practice, significantly reduce scan time while maintaining high image quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.008
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: none
Teacher disagreement score0.994
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0080.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.340
Teacher spread0.326 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular Magnetic ResonanceSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207