B-053 Investigation of Discrepant Alkaline Phosphatase Results on the Roche Cobas Pro Instrument

2025· article· en· W4414740893 on OpenAlexaffabout
Josh Raizman, Keri Niemann, Isolde Seiden Long, Yury Butorin, Allison A. Venner, Karin Moses

Bibliographic record

VenueClinical Chemistry · 2025
Typearticle
Languageen
FieldMedicine
TopicAlkaline Phosphatase Research Studies
Canadian institutionsRed Deer PolytechnicCalgary Laboratory Services
Fundersnot available
KeywordsVacutainerAlkaline phosphataseRoche DiagnosticsSignificant differenceMean difference

Abstract

fetched live from OpenAlex

Abstract Background A high frequency of Roche Cobas delta check instrument errors for alkaline phosphatase (ALP) led to the discovery of non-reproducible and spurious ALP results in a tertiary care hospital. A series of studies were subsequently performed on different Roche instruments at multiple hospital laboratories across Alberta, Canada, to determine the root cause and develop workflow mitigation strategies. Methods Three studies were implemented across different hospital laboratories to quantify frequency and identify cause of ALP fliers. ALP was measured on the Roche Cobas Pro c503 at 12 sites and on Roche Cobas 8000 c702 at 1 site. Replicates that exceeded the total allowable error (TAE) of =150 U/L ± 15 U/L or >150 U/L ± 10% were considered discrepant. Firstly, ALP samples run in duplicate and those exceeding the TAE were aliquoted, respun and reanalyzed in for 1-9 months. In the second study, ALP collections in BD Vacutainer plasma separator tubes (PST) were switched to BD Vacutainer Barricor tubes, which produce cleaner plasma, and run in duplicate for 1 month. Lastly, ALP was diluted (5x) and analyzed in duplicate. If TAE was exceeded then neat samples were aliquoted, respun and rerun. Results The first phase identified 563 ALP repeats outside the TAE across the Pro sites but none on the 8000. Frequency of spurious results varied at sites and ranged from 0.3-12/week and 0.04-1.5% of total ALP testing volumes. Initial duplicate comparisons had an overall mean difference (standard deviation, SD) of 15.1% (38.2%), and difference range of -85 to 270% across sites. Respinning significantly improved comparison results, with the percent mean (SD) decreasing to 0.3% (3.2%) and a narrower difference range of -13.5 to 41%. Barricor tubes reduced overall ALP flier rate by 72% and 5x dilutions reduced them by 89%. Conclusion Clinically significant ALP discrepancies were identified on multiple Roche Cobas Pro instrument across a large provincial laboratory network. These fliers were not observed on the Roche Cobas 8000, and were largely eliminated after respinning, dilution, and use of Barricor tubes, suggesting a preanalytical cause. This also suggests that the Pros may be more prone to interference from plasma contaminants. An automated workflow protocol involving a combination of onboard dilution of all ALP samples with respin only if TAE is exceeded was developed as a cost-effective and streamlined approach to minimize these errors.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.020
metaresearch head score (Gemma)0.018
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score0.105

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0200.018
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.003
Science and technology studies0.0010.002
Scholarly communication0.0030.000
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0060.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.094
GPT teacher head0.406
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueClinical ChemistrySame topicAlkaline Phosphatase Research StudiesFrench-language works237,207